Testing & Troubleshooting

Mic never active

• Check that the type of precedence setting is correct for the application

(See page 26).

• If mic is a condenser type, check that phantom power is applied to mic

input (see page 27)

• Check that mic is assigned to the amp in question (see page 24).
• If Mic B is the problem, check that it is not set for Tel operation (see

page 27).

Mic distorted

• Reduce volume until output is not distorted.
• Check if ALC for that mic is turned on (see page 27).

Tel input distorted

• Make sure no DC voltage is connected to the Tel input.
• Check that Mic B is set for Tel operation (see page 27).

Aux always active

• Check if Aux is manually selected.
• Check for high levels of hum and noise from source.

Aux never active

• Check if Aux is assigned to amp in question (see page 24).
• No or very low audio signal present at aux input in question.

Music cuts in late

• Trim pad set incorrectly (see page 10).
• Energy content of music very low.

No control over volume or tone

• Check that the correct amp is selected (see page 7).
• If INHIBIT appears on the display when arrow buttons are pushed, the

function has been programmed not to respond. (see page 32).

Forgot password

• Reset password (see page 35).