Environmental requirements, Power cords (japan, denan) – Brocade Communications Systems Extension Switch 7800 User Manual

Page 43

Advertising
background image

Brocade 7800 Extension Switch Hardware Reference Manual

31

53-1001350-04

Environmental requirements

A

Table 8

lists the power supply specifications for the Brocade 7800.

Environmental requirements

Table 9

lists the acceptable environmental ranges for both operating and nonoperating (such as

during transportation or storage) conditions

Power cords (Japan, Denan)

TABLE 8

Power supply specifications

Specification

Value

Maximum output of one power supply

150 watts

System DC power consumption (excluding
power supply and fan FRUs)

Idle: 95 W
Maximum: 116 W

Input system power (including power supply
and fan FRUs)

Idle: 145 W
Maximum: 173 W

Input voltage

85-264 VAC

Input line frequency

47-63 Hz

BTU rating

590 BTU/hr

Inrush current

Maximum of 60A for period of 10-150mS

Input line protection

Both AC lines are fused

TABLE 9

Environmental requirements

Condition

Acceptable during operation

Acceptable during non-operation

Ambient Temperature

0º to 40º C
32º to 104º F

-25º to 70º C
-13º to 158º F

Humidity

10% to 85% RH non-condensing, at
40º C (104º F)

10% to 90% RH non-condensing, at
70º C (158º F)

Altitude

0 to 3 km (9,842 feet) above sea level

0 to 12 km (39,370 feet) above sea
level

Shock

20 G, 6 ms, half-sine wave

15 G, 12-18 ms, trapezoid

Vibration

0.5 G sine, 5-500 Hz

2.0 G sine, 5-500 Hz

Air flow

Maximum - 101.94 cmh (60 cfm)
Nominal - 74.76 cmh (44 cfm)

NA