Installation

Connecting the Servers:

Step 1

Connect all servers to the primary and secondary KVM switches. Refer to
the “Connecting Servers to the SMB CAT5 KVM Switch” section on page 17
for instructions.

Step 2

Make sure that the power adapter is connected to the primary KVM switch
and that the KVM switch is powered on. You should see the primary KVM
switch light up and display the digits “00”, indicating its BANK address.

Step 3

Power up the secondary KVM switches sequentially, beginning with BANK
01, by connecting each unit’s power supply. Each KVM switch should display
its corresponding BANK address number as it is powered up.
NOTE: If the SMB CAT5 KVM Switches do not enumerate correctly, reset the

primary KVM switch (BANK 00) by simultaneously pressing the “BANK +” and

“BANK –” buttons. You can also reset the primary KVM switch to detect newly

added secondary KVM switches. If the KVM switches still do not enumerate

correctly, check that all KVM switches have the correct BANK address assigned

to them and that all daisy-chain cables are connected properly.

Step 4

Verify that the primary KVM switch has detected all secondary KVM switches
by scrolling through the BANKS using the “BANK +” and “BANK –” buttons.
If all secondary KVM switches are detected properly, the LED display on
the primary KVM switch will register and display the BANK address of the
attached secondary KVM switch.