Please do not return this product to the store, Roubleshooting – Bissell PROHEAT 25A3 User Manual

Page 16

Advertising
background image

w w w . b i s s e l l . c o m

8 0 0 . 2 3 7 . 7 6 9 1

16

T

roubleshooting

Heat indicator light does not illuminate:

Possible causes

Remedies

1. The heater switch is not turned on.

1. Turn on the heater switch located on side of unit

2. The machine power switch is not turned on

2. Both switches must be on to activate the

heat indicator light.

Reduced or no spray

Possible causes

Remedies

1. Bladder may be empty.

1. Refill bladder with hot tap water

2. 2-in-1 tank may not be seated properly.

2. Remove and reseat 2-in-1 tank

3. Pump may have lost prime.

3. Turn power off and hold spray trigger for 30 seconds. Turn

machine back on and check for spray

4. The pump belt may be broken.

4. Turn power switch off and unplug

from the outlet. To check if a pump belt has

broken, you will need a flat head screwdriver.

a. Insert the flat end into the slot of the

belt access door to release. Examine the

belt for breakage. You should be able to see

the pump belt looped around the motor shaft.

If it is broken or missing, please refer to

Replacement Parts on page 17.

A replacement belt may be ordered at

www.bissell.com or by calling BISSELL

Consumer Services at 800-237-7691.

Complete installation instructions will accompany the

replacement belt.

b. When replacing belt access door be sure to

line up slots of belt access door with slots in

machine, slide door into place and snap shut.

Other maintenance or service not included in the manual should be

performed by an authorized service representative.

Thank you for selecting a BISSELL product.

Please do not return this product to the store.

For any questions or concerns, BISSELL is happy to be of

service. Contact us directly at 1-800-237-7691.

Slots

a.

b.

Pump Belt

Advertising