1. Important

Guidance and manufacturer’s declaration – electromagnetic immunity – for all EQUIPMENT and
SYSTEMS:

7KHPRQLWRULVLQWHQGHGIRUXVHLQWKHHOHFWURPDJQHWLFHQYLURQPHQWVSHFLÀHGEHORZ7KHFXVWRPHURUWKHXVHURI
the monitor should assure that it is used in such an environment.

Immunity test

IEC 60601 test level

Compliance level

Electromagnetic environment –
guidance

Electrostatic
discharge (ESD)

IEC 61000-4-2

6 kV contact

8 kV air

6 kV contact

8 kV air

Floors should be wood, concrete or
FHUDPLFWLOH,IÁRRUVDUHFRYHUHGZLWK
synthetic material, the relative humidity
should be at least 30%.

Electrical fast
transient/burst
IEC 61000-4-4

2 kV for power supply
lines

1 kV for input/output
lines

2 kV for power supply
lines

1 kV for input/output
lines

Mains power quality should be that
of a typical commercial or hospital
environment.

Surge

IEC 61000-4-5

1 kV line(s) to line(s)

2 kV line(s) to earth

1 kV line(s) to line(s)

2 kV line(s) to earth

Mains power quality should be that
of a typical commercial or hospital
environment.

interruptions and
voltage variations
on power supply
input lines

IEC 61000-4-11

<5 % UT (>95 % dip in
UT) for 0.5 cycle

40 % UT (60 % dip in
UT) for 5 cycles

70 % UT (30 % dip in
UT) for 25 cycles

<5 % UT (>95 % dip in
UT) for 5 sec

<5 % UT (>95 % dip in
UT) for 0.5 cycle

40 % UT (60 % dip in
UT) for 5 cycles

70 % UT (30 % dip in
UT) for 25 cycles

<5 % UT (>95 % dip in
UT) for 5 sec

Mains power quality should be that
of a typical commercial or hospital
environment. If the user of the monitor
requires continued operation during
power mains interruptions, it is
recommended that the monitor be
powered from an uninterruptible power
supply or a battery.

Power frequency
(50/60 Hz)
PDJQHWLFÀHOG

IEC 61000-4-8

3 A/m

3 A/m

3RZHUIUHTXHQF\PDJQHWLFÀHOGVVKRXOG
be at levels characteristic of a typical
location in a typical commercial or
hospital environment.

Note

UT is the a.c. mains voltage prior to application of the test level.