Service (cont.) – Bunn FMD-1 User Manual

Page 27

Advertising
background image

27

for two wire 120 volt models, three wire 120/208
and 120/240 volt models.

4. Disconnect the dispenser from the power source,

If voltage is present as described, proceed to #5
If voltage is not present as described, refer to the

wiring diagram and check dispenser wiring har-
ness.

5. Check for continuity across the solenoid valve coil

terminals.

If continuity is present as described, reconnect the

white and violet wires to the solenoid.

If continuity is not present as described, replace the

solenoid valve.

6. Check the solenoid valve for coil action. Connect

the dispenser to the power source. Listen carefully
in the vicinity of the solenoid valve for a "clicking"
sound as the coil magnet attracts.

7. Disconnect the dispenser from the power source.

If the sound is heard as described and water will not

pass through the solenoid valve, there may be a
blockage in the water line before the solenoid valve
or, the solenoid valve may require inspection for
wear, and removal of waterborne particles.

If the sound is not heard as described, replace the

solenoid valve.

Removal and Replacement:
1. Remove the white and violet wires from the sole-

noid valve.

2. Turn-off the water supply to the dispenser.
3. Disconnect the water lines to and from the sole-

noid valve.

4. Remove the two #10-32 screws securing the so-

lenoid to the rear of the dispenser housing. Re-
move solenoid.

5. Remove the two #8-32 U-Type fasteners from the

solenoid bracket.

6. Install the two #8-32 U-Type fasteners and the two

#8-32 screws on the new solenoid.

7. Install new solenoid on rear of dispenser housing

and tighten the two scrrews

8. Securely fasten the water lines to and from the

solenoid valve.

9.

Refer to Fig. 27 when reconnecting the wires.

SERVICE (cont.)

FIG. 25 DISPENSE SOLENOID VALVE

TERMINALS

P1231

6. Using the #10-32 screw install new solenoid valve

on side of the tank

7. Push the water line onto the tube on bottom of

solenoid valve.

8. Refer to Fig. 25 when reconnecting the wires.

SOLENOID VALVE (DISPENSE)

SOLENOID VALVE (INLET)

FIG. 26 INLET SOLENOID VALVE

Location:

The inlet solenoid is located on the lower right

side of the rear panel.

Test Procedures:
1. Disconnect the dispenser from the power source.
2. Disconnect the white and violet wires from the

solenoid valve.

3. Check the voltage across the white and violet wires

with a voltmeter. Connect the dispenser to the
power source. The indication must be 120 volts ac

P1505

WHI/RED to Auger Motor

WHI to Main Harness

28364 041598