Product will not dispense (cont.)

Water is not hot

5. Solenoid valve (inlet)

6. Level control board and probe

7. Overflow protection switch

8. Auger drive

9. Water strainer

10. Lime build-up
CAUTION - Tank and tank compo-
nents should be delimed regularly
depending on local water conditions.
Excessive mineral build-up on stain-
less steel surfaces can initiate corro-
sive reactions resulting in serious
leaks.

1. Limit thermostat
CAUTION - Do not eliminate or by-
pass limit thermostat. Use only BOM
replacement part #29329.1000

2. Control thermostat

3. Tank Heater

Refer to

Service

- Solenoid Valve

(Inlet) for testing procedures. See
page 27

Refer to

Service

- Level Control Board

and Probe for testing procedures.
See page 22

Refer to

Service

- Overflow protec-

tion switch for testing procedures.
See page 24

Refer to

Service

- Auger Drive. See

page 12

(A) Direction of flow arrow must be
pointing towards brewer.

(B) Remove the strainer and check
for obstructions. Clear or replace.

Inspect the tank assembly for exces-
sive lime deposits. Delime as re-
quired.

Refer to

Service

- Limit Thermostat

for testing procedures. See page 24

Refer to

Service

- Control Thermo-

stat for testing procedures. See page
15

Refer to

Service

- Tank Heater for

testing procedures. See page 28

TROUBLESHOOTING (cont.)

PROBLEM

PROBABLE CAUSE

REMEDY