TANK HEATER

FIG. 28 TANK HEATER

Location:

The tank heater is located inside the tank and

secured to the tank lid.

Test Procedure:
1. Disconnect the dispenser from the power source.
2. Check the voltage across the black and white wires

120 volt models or black and red wires for 120/208
volt models or 120/240 volt models with a voltme-
ter. Connect the dispenser to the power source.
The indication must be:
a) 120 volts ac for two wire 120 volt models;
b) 208 volts ac for three wire 120/208 volt models.
c) 240 volts ac for three wire 120/240 volt models.