Quick reference guide, Easy select board thermidistat™ control settings – Bryant 683B User Manual

Page 28

Advertising
background image

ICM QUICK REFERENCE GUIDE

c01034

EASY SELECT

HEATER/MOTOR

AUX HEAT KW/CFM

0-30

1075

SEC1

SEC2

J1

AC/HP SIZE

036

030

024

018

AC

HP-COMFORT

HP-EFF

NOM

HI

ENH

LO

SYSTEM TYPE

AC/HP CFM ADJUST

ON/OFF DELAY

CONTINUOUS FAN

MED

HI

YEL

LO

AUX1

HUM1

AUX2

24VAC

GRY

HUM2

YEL

WHT

BLK

ORN

BLU

VIO

0-20

875

0-10

725

0

90

30
90

0
0

0-5

625

TM

J2

D

H

R
W

1

W

2

Y

1

Y/Y

2

G
O
C

QUICK REFERENCE GUIDE

SET-UP INSTRUCTIONS FOR WARMER HEATING TEMPERATURES

AND SUPER HUMIDITY CONTROL IN COOLING

A. AUX HEAT - Set for heater size (Ex: 0-10 for 10 kw)
B. AC/HP SIZE - Set for size of outdoor unit
C. SYSTEM TYPE - Select "HP COMFORT"
D. AC/HP CFM ADJUST - Select "LO"
E. ON/OFF DELAY - Select "ENH"
F. CONTINUOUS FAN - Select desired speed
2. Remove Jumper J1 to activate all dehumidify modes.
3. Complete wiring and install outdoor temperature sensor

according to Installation Instructions.

1. Configuration Taps

(See Installation Instructions, for detailed description.)

• Option 5 (Variable Speed Motors) - set to ON
• Option 7 (Super Dehumidify) - set to ON
• Option 12 (Heaters during Defrost) - setting "2" is
suggested for all heaters
• Option 16 - Heat pump systems set to ON for warmer heat
below 40

°

F.

Option 17 - Select programmable or non-programmable mode.

2. Thermidistat Control Configurations

(See Thermidistat™ Control Installation Instructions for

detailed description.)

3. Set desired humidity level on front of Thermidistat
(50 to 55% RH recommended). For dehumidification in
cooling, both "dhu" and "cool" must be displayed.

1. Set "DIP Switches" - Set the dip switches (back of Thermidistat

Control Board) appropriately for specific system being installed.

EASY SELECT BOARD

THERMIDISTAT™ CONTROL SETTINGS

9 PIN CONNECTOR

ICM PRINTED CIRCUIT BOARD

12 PIN CONNECTOR

A

B

C

D

E

F

TABLE 24—TROUBLESHOOTING CHART

SYSTEM

CAUSE

REMEDY

IFM does not run

Blower wheel not secured to shaft

Inspect and properly tighten blower wheel to shaft

Insufficient voltage at motor

Determine cause and correct

Power connectors not properly seated

Connectors should snap easily; do not force

IFM operation is intermittent

Connectors not firmly seated

Gently pull wires individually

to be sure they are inserted

into the connectors

—28—