SERVICING AND REPAIR

H-5 Paint Mixer Operating & Instruction Manual

23

CHANGING MOTOR

Read all of the following instructions. If you have any doubt about
performing these procedures, please contact Customer Service at Fluid
Management. Turn to the Parts Section of this manual for component
identification and location.

1. Unplug the power cord from the electrical outlet.

2. Close front cover of the machine.

3. Release the two (2) latches as shown and open rear of machine.

4. The belt tension is adjustable with an adjustment bolt and locking nut.

To remove belt back off the locking nut and adjust with adjustment bolt
as shown in “Belt Adjustment” on page 25.

5. Remove belt and save as required.

6. Remove the plate covering the motor saving mounting screws for reas-

sembly.

7. Remove cover plate from motor and sketch the wire connections.

8. Remove the three (3) conductors of the power cable that leads to the

device.

9. The motor is foot-mounted. Remove mounting bolts and motor.

10. Using the same mounting hardware, mount the replacement motor.

11. Refer to the sketch, terminate the three (3) motor conductors of the

power cable that leads to the device.

12. Place the plate covering the motor as it was earlier.

13. Install belt as shown in “Belt Adjustment” on page 25.

14. Tension is properly adjusted when approximately four (4) lbs. of force

deflects belt 1/4".

15. Close back cover of machine and secure with latches.

16. Plug machine into power source and test as required.

The mixer must be unplugged before
attempting this procedure. There is a
chance of electrical shock.

WARNING: ELECTRICAL HAZARD