6 Testing & Final Assembly

30

!

Turn the compressor (or alternate air source) on to charge the air

supply up to its maximum pressure.

!

Rotate one wheel by hand.

!

The wheel should rotate freely and the opposite wheel should be

turning in the opposite direction without any resistance or
mechanical noise from within the differential.

!

Turn the Air Locker switch to the ‘ON’ position. The illuminated

symbol on the switch cover should light up.

!

Rotate the same wheel again.

!

Both wheels should rotate together.

!

Turn the switch off again.

!

Rotate the same wheel.

!

The wheels should again rotate in opposite directions.

6.3

Filling the Differential

NOTE : Consult the ARB Air Locker Operating & Service

Manual for recommendations on differential lubricant
specifications.

!

Refill the differential until level with the filler hole.

!

Rotate the differential center 2 full turns.

!

Check the oil level and add oil if necessary.

!

Apply thread sealant to filler plug before inserting.

!

Replace the filler plug.

!

Clean the differential housing of any oil or grease that may collect

dirt or other abrasive particles.