3 installing the air locker – ARB RD100 User Manual

Page 26

Advertising
background image

3 Installing the Air Locker

24

c Install the shim pack ‘D’ between the master shim and the seal

housing as shown in Figure 13.

c Spread the differential housing again (Refer to Section 2.6).
c Re-install the Air Locker into the axle housing.

NOTE : If the Air Locker is too tight to fully install then the

spreader tension may need to be increased. Do not
spread the housing more than 0.50mm [0.020”].

c Rotate the seal housing until the tube is positioned in the center of

the oil drainage notch of the axle housing. (Fig.19.)

Figure 19.

c Release all spreader tension.
c Check that some backlash can be felt between the ring and pinion

gears. No backlash would be an early indication of incorrect shim
thickness.

Advertising