6 Testing & Final Assembly

34

c Turn the compressor (or alternate air source) on to charge the air

supply up to its maximum pressure.

c Rotate one wheel by hand.
c The wheel should rotate freely and the opposite wheel should be

turning in the opposite direction without any resistance or
mechanical noise from within the differential.

c Turn the Air Locker switch to the ‘ON’ position. The illuminated

symbol on the switch cover should light up.

c Rotate the same wheel again.
c Both wheels should rotate together.
c Turn the switch off again.
c Rotate the same wheel.
c The wheels should again rotate in opposite directions.

6.3

Filling the Differential

NOTE : Consult the ARB Air Locker Operating & Service

Manual for recommendations on differential lubricant
specifications.

c Refill the differential until level with the filler hole.
c Rotate the differential center 2 full turns.
c Check the oil level and add oil if necessary.
c Apply thread sealant to filler plug before inserting.
c Replace the filler plug.
c Clean the differential housing of any oil or grease that may collect

dirt or other abrasive particles.

Advertising