L.B. White FA-MCS User Manual

Page 11

Advertising
background image

Press the center soft key EDIT. The following screen will be
displayed.

FIG. 20

Using the up/down keys, select either “‘ENA” to enable the
manual override or “dSA” to disable the override.

ENABLE (Manual Mode)
-- If enable is selected, press the right soft

key NEXT and then up/down keys to set the
temperature that will be maintained by the
SmartBox

. See Fig.21.

-- Once the temperature has been selected , press the

left soft key DONE.

-- Zone 1 is now in manual override. After ensuring

the room controller and Smart Box

set points are

aligned, no further action is needed.

FIG. 21

DISABLE (Operating on Temperature Curve)

-- Selecting disable deactivates the manual override,

allowing the SmartBox

to operate within the

temperature curve.

-- Press the right soft key NEXT. The following screen

will be displayed. Complete the same enabling

or disabling process for Zone 2 as you previously did

for Zone 1.

FIG. 22

--

Press the right soft key NEXT to continue. The screen
shown in Fig.23 will be displayed.

FIG. 26

Press the right soft key NEXT to continue set-up. The

screen shown in Fig.24 will be displayed.

SET CLOCK (To run the temperature curve the clock must be

set)

FIG. 24

Press the center soft key EDIT to set the clock.

-- Starting with the Month, use the up/down keys to

select Month, day, year, hour, (Note; AM or PM) and
Minutes.

-- Press left soft key DONE to return to SET CLK.

Press the right soft key NEXT to continue set-up.

TEMPERATURE SENSORS

The following screen is displayed. There are two

temperature sensors for Zone 1 and two temperature
sensors for Zone 2. This screen gives you the option for
either using only one or two sensors for either zone. YOU
MUST USE AT LEAST ONE SENSOR.

FIG. 25

11