L.B. White FA-MCS User Manual

Page 14

Advertising
background image

Press the up/down keys to set the Period 2 day as
determined with the Temperature Curve.

Press the right soft key NEXT. The following screen is
displayed. Enter the desired set point for Period 2 Zone 1
using the up/down keys.

FIG. 36

Press the right soft key NEXT and enter the set point for
Period 2 Zone 2 using the up/down keys.

Press the left hand soft key DONE.

Repeat this this same process for Periods 3 through 10,
setting the number of days and set points.

Press the left soft key DONE.

Simultaneously press the middle soft key and up/down
keys to return to the Home Screen. Set up is complete.

SCREEN DISPLAYS

-- Z1 OR EN (Zone 1 Override Enabled)

-- Z1 TSP OR ( Zone 1 Temperature Set Point Override)
-- Z1 OR ENA or dSA (Zone 1 enabled or disabled)
-- Z2 OR EN (Zone 2 Overide Enabled)
-- Z2 TSP OR (Zone 2 Temperature Set Point Override)
-- STRT DAY (Start Day)
-- Time
-- SCHD DAY (Schedule Day)
-- ACT Period (Actual Period)
-- RMNG HRS (Remaining Hours)
-- Z1 ACTSP (Zone 1 Actual Set point)
-- Z2 ACTSP (Zone 2 Actual Set Point)
-- Z1 T1, T2, (Zone 1 Temperature Sensor 1, etc.)
-- Z2 T1 ( Zone 2 Temperature Sensor 1)
-- Z1 T Avg (Zone 1 Temperature Sensor Average)
-- Z2 T Avg (Zone 2 Temperature Sensor Average)
-- SCHED ER (Schedule Error)
-- HTG STS (Heating Status)
-- Z1 Htg Ld (Zone 1 Heating Load)*
-- Z2 Htg Ld (Zone 2 Heating Load)*
-- P1 T SP(Period 1 through 10 Temperature Set Point)
-- P-1 (Set Point for Period 1,Zone 1)
-- P-1 Z-2 (Set Point for Period 2 Zone 2)
-- P2 Day (Period 2 Day through Period 10 Day)
-- Sen Dis (Sensor Disabled)
-- Z1 T1 and T2 Disabled
-- Z2 T1 and T2 Disabled
-- TMP OF SET( Temperature off set)
-- OF ST T1 (or T2) (Off set Temperature Sensor 1 or 2)
-- Status
-- Set Clk (Set Clock)

-- Month
-- Day
-- Year
-- Hour
-- Minutes

* Percentage of operation of variable rate gas control valves