Refer to Fig.3 and follow steps 1 - 5 on initial start-up. For

normal start-up, follow steps 2 and 3.

1. Open all manual fuel supply valves and check for gas

leaks using approved leak detectors.

2. Connect the heater’s electrical cord to an approved

electrical supply. The fan motor will start and the

igniter will spark.

3. Fully depress the button on the safety control valve.

The burner will light. Keep the button depressed for

about 30 seconds or until the thermocouple has

warmed up. Release the button. The burner will stay

lit.

4. Turn the adjustment valve on the heater to either

high or low heat positions as desired.

5. Do not exceed the input rating stamped on the

dataplate of the heater. Do not use an orifice size

different than specified for the input rating of this

heater, fuel type configuration and altitude.

FIG. 3

If the heater is to be shut down after normal use, and

further use is anticipated, disconnect the heater from

its electrical supply.

If the heater will not be used until later, disconnect the

electrical supply and close all fuel supply valves to the

heater’s gas inlet.