Service instructions, Motor and fan assembly thermocouple, Burner orifice – L.B. White 100 Tradesman Portable Forced Air User Manual

Page 14: Attention, Fig. 7, Fig. 6, Fig. 8

Advertising
background image

1. Disconnect the thermocouple contact nut from the

pilot safety control valve.

2. Disconnect the two electrical leads from the energy

cut off block on the thermocouple.

3. Pull the thermocouple from its retaining clip.

ATTENTION

When properly installed, the tip of the thermocouple will

extend 1/2 in. from the retaining clip on the combustion

side of the burner plate.

When tightening the contact nut of the thermocouple,

thread the nut in fingertight and snug it in place a

wrench.

FIG. 7

1. Loosen the set screw on the fan hub and slide the fan

off of the fan shaft.

2. Remove the nut and bolt that secure the motor

within the motor mount.

3. When installing motor and fan:

-- Ensure motor is centered within the motor mount.

-- Set screw of fan must be located over flat of motor

shaft before tightening

-- Position fan so side opposite of fan hub is flush with

end of shaft

-- Spin the fan to make sure it does not hit heater

components.

FIG. 6

Service Instructions

MOTOR AND FAN ASSEMBLY

THERMOCOUPLE

BURNER PLATE

THERMOCOUPLE

CLIP

1/2 INCH

BURNER ORIFICE

RING, FLAT

ORIFICE

BURNER PLATE

RING, BOWED

MANIFOLD

1. Loosen the compression nut at the orifice inlet.

2. Remove the bowed retaining ring nearest the

compression nut.

3. Reach down the heater barrel, and pull the orifice

from the burner plate.

4. The replacement orifice ships with two retaining rings.

Push the flat ring into the slot nearest the orifice

holes. Reaching down the barrel, position the orifice

into the burner plate. Secure the orifice into position

using the bowed retaining clip.

FIG. 8

13

MOTOR CENTERED

IN MOUNT

FRONT OF HUB

FLUSH AT

SHAFT END

MOTOR

HUB

SIDE
OPPOSITE
HUB

Advertising