Heater specifications, Model – L.B. White 100 Tradesman Portable Forced Air User Manual
Page 5
SPECIFICATIONS
Maximum Input (BTUH)
100,000
Minimum Input (BTUH)
50,000
350 CFM
1/15 H.P.
3200 RPM
4.7
2
25 1/4 x 9 3/4 x 14
TOP
6 ft.
SIDES
2 ft.
BACK
2 ft.
BLOWER OUTLET
GAS SUPPLY
-20º F
22
28
CP100
Propane
Gas
Model
Ventilation Air Required
to Support Combustion
Fuel Type
Net Weight (lbs.)
Shipping Weight (lbs.)
Electrical Supply
(Volts/Hz/Phase)
Amp Draw
Dimensions (Inches)
L x W x H
Minimum Safe Distances From
Nearest Combustible Materials
Minimum Ambient Temperature
In Which Heater May Be Operated
STARTING
CONTINUOUS
OPERATION
Motor Characteristics
Fuel Consumption Per Hour
Inlet Gas Supply
Pressure Acceptable
at the Inlet of the
Heater for Purpose
of Input Adjustment
MAX.
MIN.
MAX.
MIN.
11 in. W.C.
11 in. W.C.
4.63 lbs.
2.32 lbs.
Ball Bearing
6 ft.
6 ft.
(1.83m)
115/60/1
Heater Specifications
4