R E A D T H I S E N T I R E S E C T I O N B E F O R E
BEGINNING TO TROUBLESHOOT PROBLEMS.

The following troubleshooting guide provides systematic

procedures for isolating equipment problems. This guide is

intended for use by a QUALIFIED GAS HEATER SERVICE

PERSON. DO NOT ATTEMPT TO SERVICE THESE HEATERS

UNLESS YOU HAVE BEEN PROPERLY TRAINED.

TEST EQUIPMENT REQUIRED

The following pieces of test equipment will be required to

troubleshoot this system with minimal time and effort.

• Digital Multimeter - for measuring AC and DC voltage

and resistance.

• Low Pressure Gauge - for checking inlet and manifold

pressures at the gas control valve against dataplate

rating.

Visually inspect equipment for apparent damage.

Check all wiring for loose connections and worn

insulation.

Use the flow charts on the following pages to troubleshoot

problems. To use the charts effectively, you must first

identify the problem. The problems are numbered along

with a brief explanation of each problem. Start at the

diamond closest to the identified problem and proceed with

each step, performing the suggested tests. After each step

or test, the guide will direct the service person to the next

logical step based on the outcome of the previous check.

Components should be replaced only after each step has

been completed and replacement is suggested in the flow

chart.

The problems are listed below along with the page number

on which you may find the flow chart for the specific

problem.

Problem

Description

Page

1. Fan Motor Does Not Run . . . . . . . . . . . . . . . . . . . . . . . .17

2. Fan Motor Runs, Heater Does Not Light . . . . . . . . . . . .17

3. Burner Flame Drops Out After 10-15 Minutes

Of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17

4. Heater Lights But Does Not Stay Lit . . . . . . . . . . . . . . .18

5. Backflash Switch is Open . . . . . . . . . . . . . . . . . . . . . . .18

Troubleshooting Guide

WARNING

Electrical Shock and Burn Hazard

Troubleshooting this system may require operating the

unit with line voltage present and gas on. Use extreme

caution when working on the heater.

Failure to follow this warning may result in property

damage, personal injury or death.