GAS CONTROL VALVE

CAP

SAFETY CONTROL VALVE

LOW PRESSURE GAUGE

5

0

10

15

20

25

30

35

1. Remove the cap on the underside of the control valve.

See Fig.11.

2. Connect a pressure gauge at this point, capable of

reading up to 35 in. W.C. (L.B. White gauge part

number 00764.)

3. Reconnect the heater to its electrical supply and open

the fuel supply valves to the heater.

4. When the burner lights, the flowing gas pressure

must be 11 in. W.C. If not, either of the following

conditions exist:

a. Gas control inlet screen is plugged with debris.

Disassemble as needed. Remove the inlet screen

and clean with compressed air, or replace.

b. Single stage regulator is out of adjustment.

Replace the regulator.

5. After checking, remove gas gauge. Reinstall cap

(tighten securely).

FIG. 11

WARNING

Fire and Explosion Hazard

Do not disassemble the safety control valve.

Do not attempt to replace any component of the safety

control valve.

The safety control valve must be replaced if any

damage occurs to the valve.

Failure to follow this warning will result in fire or

explosion, leading to sever injury, death, or property

damage.