Electric Outlet

TO START HEATER

1. Fill fuel tank with kerosene or No. 1 fuel oil.

2. Attach fuel cap.

3. Plug power cord into three prong, grounded extension

cord. Extension cord must be at least six feet long.
- Extension Cord Wire Size Requirements:

- 6 to 100 feet (1.8 to 30.53 meters) long, use 16

AWG conductor.

- 101 to 200 feet (30.8 to 61 meters) long, use 14

AWG conductor.

NO THERMOSTAT ON 45

4. Turn thermostat control knob to desired setting and
push power switch to “ON” position. Power lamp will
light and heater will start.

NOTE

: Room Temp. display indicates as following:

- When room temp. is less than 0

ºF

: “lo”.

- When room temp. is between 0

ºF

and 99

ºF

:

“Temp. is Displayed”

ºF

: “Hi”

9

9

n

a

h

t

r

e

t

a

e

r

g

s

i

p

m

e

t

m

o

o

r

n

e

h

W

-


If heater does not start, the thermostat setting

may be too low. Turn THERMOSTAT CONTROL

KNOB to higher position to start heater. If heater

still does not start, turn power switch to “OFF”

and then to “ON” position (See Figure 7.1 &7.2)

If heater still does not start, see Troubleshooting

on page 18.
NOTE: The major electrical components of this

heater are protected by a safety fuse mounted to

the PCB board. If your heater fails to start, check

should also check your power source to insure

that proper voltage and frequency are being

supplied to the heater.

Model CP045DK

Model CP125EK, CP175EK, CP210EK

Model CP075DK

Figure 7.1 - Controls

Figure 7.1 - Controls

Figure 7.2 - Controls

OPERATION (cont.)

FUELING YOUR HEATER

TO SHUT DOWN HEATER

TO RESTART HEATER

PIGGYBACK POWER CORD

tank outdoors.

Turn switch to “OFF” and unplug power cord.

1. Wait 10 seconds after stopping heater.

2. Repeat steps under, “TO START HEATER.”

WARNING

WARNING

Fire and explosion hazard!

SHOCK HAZARD!

still hot.

• Always cover electric outlet when not in use.

Don’t plug and use an appliance of more than

5A current in this outlet.

IMPORTANT :

REGARDING FIRST IGNITION OF

be done OUTDOORS. This allows the oils, etc., used

in manufacturing heater to be burned off outside.

Lamp

Power/Reset Switch

Power/Reset

Switch

Lamp

Thermostat Control Knob

Power/Reset

Switch

Lamp

Thermostat

Control Knob

Room Temp. Display