Maintenance (cont.), Spark plug photocell – L.B. White 125-210K Tradesman User Manual

Page 16

Advertising
background image

MAINTENANCE (cont.)

Figure 18 – Spark Plug Replacement

Figure 20 – Photocell Replacement

Figure 19 – Spark Plug Replacement

SPARK PLUG

PHOTOCELL

CLEAN AND REGAP EVERY 600 HOURS OF OPERATION OR

REPLACE AS NEEDED.

Ignitor Wire

Screw

Spark Plug

Nozzle Adaptor

Spark Plug

GAP

(For Models CP045DK-CP175EK)
- Remove upper shell (See Air Intake Filter, page 12).
- Remove fan (See Fan Blades, page 13).
- Remove ignitor wire from spark plug.
- Remove spark plug from nozzle adaptor using
medium phillips screwdriver.
- Clean and regap spark plug electrodes to 3.5mm gap.
- Reinstall spark plug to nozzle adaptor.
- Attach ignitor wire to spark plug.
- Reinstall fan and upper shell.

CLEAN PHOTOCELL ANNUALLY OR AS NEEDED.
- Remove upper shell (See Air Intake Filter, page 12)
- Remove fan (See Fan Blades, page 13)
- Remove photocell from its mounting bracket.
- Clean photocell lens with cotton swab.
TO REPLACE: Remove side cover near power switch.
- Disconnect wires from power switch and remove
side cover.
- Disconnect wires from circuit board and remove
photocell.
- Install new photocell and attach wires to circuit board
- Replace switch wires to power switch and side cover.
- Replace fan and upper shell.

(For Model CP210EK only)
- Remove upper shell (See Air Intake Filter, page 12).
- Remove fan (See Fan Blades, page 13).
- Remove ignitor wire from spark plug.

- Remove spark plug from nozzle adaptor using

mediumphillips screwdriver.

- Clean and regap spark plug electrodes to 3.5mm gap.

- Reinstall spark plug to nozzle adaptor.

- Attach ignitor wire to spark plug.

- Reinstall fan and upper shell.

Nozzle Adaptor

Ignitor Wire

Spark Plug

Screw

GA

P

Spark Plug

Switch

Wires

Install Photocell

Incorrect

Correct

Side Cover

Bracket

Photocell

Lens

Power

Switch

PhotocellWire

Screw

15

Advertising
This manual is related to the following products: