INSIDE STRUCTURE

SLOTS

DUCT ADAPTER
WITH TABS

TAB

DUCT KIT

A. D

Duct K

Kit

Accessory # 22841

1.. Extend the factory assembled duct kit to full length.

2. Mount duct to blower outlet of heater by inserting

tabs on duct adapter into vertical and horizontal slots

located at top and sides of blower outlet. See Fig. 4.

Push down on duct adapter to secure adapter into

outlet slots. See below for for typical installation of

heater located at exterior.

FIG. 4

OUTSIDE STRUCTURE

(Air Distribution Accessories)

SIDE WALL

500 GALLON

GAS SUPPLY

(MINIMUM)

MINIMUM SAFE DISTANCE

FROM GAS SUPPLY TO HEATER

IS 6 FEET

DISTANCE FROM HEATER TO SIDE WALL MUST

COMPLY WITH LOCAL CODES, AND BE ACCORDING

TO MANUFACTURER'S REQUIREMENTS

MINIMUM SAFE DISTANCE FROM

BLOWER OUTLET TO COMBUSTIBLES

IS 6 FEET

MINIMUM SAFE DISTANCE FROM

TOP, SIDES, AND BACK OF HEATER

TO COMBUSTIBLES IS 1 FOOT

FIG. 3

IS 10 FEET (3.04 M)

MINIMUM SAFE DISTANCE

FROM GAS SUPPLY TO

HEATER IS 6 FEET

DISTANCE FROM HEATER TO SIDE WALL MUST

COMPLY WITH LOCAL CODES, AND BE ACCORDING

TO MANUFACTURER'S REQUIREMENTS

DUCT KIT

500 GALLON

GAS SUPPLY

(MINIMUM)

SIDE WALL

TENT DRAPED

OVER DUCT

FIG. 5

MATERIAL DRAPED
OVER DUCT

IS 10 FEET (3.04 M)

Installation of Heater

10