6 -3. How to solder・How to use the solderless connectors
Caution
Wear protective gloves to avoid getting burned during soldering.
Soldering is a better choice for wiring. Make sure no loose connection is
found.
Confirmation
The solderless connectors that come with the product are for cable core of
0.3mm ~ 0.75mm diameter. Use them within the range.
Do not use the solderless connectors on wires that have thicker cable core
than 0.75mm diameter. Cable core might be broken and produce heat.
●
How to solder
●
How to use the solderless connectors
7 Operation
In this instruction, there are two kinds of ways to press buttons, "press" and
"press long." For "press," press the button for less than 1 second. For "press
long," press the button for more than 1 second.
7 -1. Setting and checking of operations
1. Turn the ignition on and check if the DC Source LED on the control unit is
lighted up.
⇒ Refer to 6 Installation.
2. Confirm that the opening ceremony is done.
⇒ Refer to 7 -2. Opening mode / Ending mode.
3. Confirm that there is no error message of wire disconnection/short circuit
on the gauges and ZDs.
⇒ Refer to 7 -3-2. Error displays of wire disconnection, short circuit, and serial error.
If an error is displayed
→ Turn the ignition off immediately, and then confirm the wiring of the
sensor and the sensor wire.
4. If the tachometer is installed, please set the number of cylinders and the response.
If ZDs are installed as well, settings for tachometer need to be done in Sys-
tem Setup Mode of ZD. The settings of ZD are applied to other tachometers
connected to the ADVANCE System. Refer to ZD manual for setting. If you
don not install either ZD or tachometer, go to next step.
⇒ Refer to 7 -4. Setting number of cylinders mode and 7 -5. Setting
Tachometer response mode.
5. Set warning values for all the connected gauges and ZDs. And then select
illumination color for CR gauges. Warning values for gauges and ZDs are
set at the same time.
⇒ Refer to 7 -6-3. Change the illumination color.
6. Confirm gauges and ZDs operate normally. Setting is finished by confirming
the operations.
Warning
Please set while the vehicle is stopped.
58
59