Lean of Peak leaning is as simple as:

A. Pre-lean your mixture.
B. Tap the LF button (verify LOP appears).
C. Lean mixture until RICHEST flashes (peak found).
D. Enrichen to the desired value ‘Lean Of Peak’.

L

Procedure

Scanner Example

Comments

1

Establish cruise at 65
to 75% power.

2

Pre-lean the mixture to
50°F estimated rich of
peak on any EGT:
_________°F.

EGT

1490

CHT

370

*

See ‘Pre-leaning’

3

Wait one minute

Let engine stabilize.

4

Tap the LF button

LOP

Start LeanFind (if ROP
appears, hold STEP & LF
until LOP appears)

5

Lean the mixture at
approx. 10°/second
without pausing.
(cylinder I.D. box
flashes when a EGT
rises 15°F)

EGT

1520

FF

13.8

Flashing cylinder I.D. box
identifies the hottest EGT and
that an EGT has increased at
least 15°F which arms the
EDM to now look for first EGT
to peak.

6

After the first EGT
peaks, you will see
LEANEST for one
second and bars
coming from the top
down. Continue
leaning.

EGT

∆

-17

FF

12.4

When bars come from the
top down, the cylinder I.D.
box identifies the first EGT
that peaked (leanest).
Continue leaning.

7

When RICHEST
appears, fine tune the
delta EGT to the
desired degrees below
‘Peak’ (Lean of peak).

EGT

∆

-45

FF

11.6

8

If you hold PEAK, the
peak EGT recorded
will be displayed along
with FF spread.

EGT

↑

1560

FF

∆

0.6

Captured peak EGT value
and the FF spread between
richest and leanest cylinders.

Advertising