Page 23

Lean of Peak leaning is as simple as:

A. Pre-lean your mixture.
B. Tap the LF button (verify LOP appears).
C. Lean mixture until RICHEST flashes (peak found).
D. Enrichen to the desired value ‘Lean Of Peak’.

L

Procedure

Scanner Example

Comments

1

Establish cruise at 65
to 75% power.

2

Pre-lean the mixture to
50°F estimated rich of
peak on any EGT:
_________°F.

EGT

1490

CHT

370

*

See ‘Pre-leaning’

3

Wait one minute

Let engine stabilize.

4

Tap the LF button

LOP

Start LeanFind (if ROP
appears, hold STEP & LF
until LOP appears)

5

Lean the mixture at
approx. 10°/second
without pausing.
(cylinder I.D. box
flashes when a EGT
rises 15°F)

EGT

1520

FF

13.8

Flashing cylinder I.D. box
identifies the hottest EGT and
that an EGT has increased at
least 15°F which arms the
EDM to now look for first EGT
to peak.

6

After the first EGT
peaks, you will see
LEANEST for one
second and bars
coming from the top
down. Continue
leaning.

EGT

-17

FF

12.4

When bars come from the
top down, the cylinder I.D.
box identifies the first EGT
that peaked (leanest).
Continue leaning.

7

When RICHEST
appears, fine tune the
delta EGT to the
desired degrees below
‘Peak’ (Lean of peak).

EGT

-45

FF

11.6

8

If you hold PEAK, the
peak EGT recorded
will be displayed along
with FF spread.

EGT

1560

FF

0.6

Captured peak EGT value
and the FF spread between
richest and leanest cylinders.