J.P. Instruments EDM 930 Primary Pilots Guide User Manual

Page 71

Advertising
background image

For Your Safe Flight

Page 66

QUICK REFERENCE

Automatic Scan

1.

Tap

LF

.

2.

Tap

STEP

.

Exclude Measurement in
Automatic Scan (toggle)

1.

Tap

STEP

to index to the

measurement to exclude.

2.

Tap both

STEP

and

LF

to

toggle exclude/include status.

3.

Decimal point before
measurement name means it is
excluded from scan.

Change Scan Indexing Rate

1.

Hold

STEP

and

LF

until the

display shows

PROGRAM

,

followed by

Refuel ?

.

2.

Tap

NEXT

, see

Auto Scan

Rate x

.

3.

Tap

PLUS or MINUS

to change

the seconds per scan: 0 to9.
Note: 0 disables auto scanning.

4.

Tap

NEXT

until you see

End?Yes,

then

EXIT

to accept

and exit.

Reset USD (Fuel Used)

1.

Tap

STEP

until

x USD

shown.

2.

Hold both

DIM

and

EGT/FF

until

.0 USD is

shown.

Display Hobbs

1.

Hold the

LF

and

DIM

buttons

simultaneously.

Download Data in Memory

1.

Insert USB Flash Drive into
front USB port on EDM.

2.

DOWNLOAD: NEW

(latest

flight) or tap

CHANGE

to see

DOWNLOAD: ALL (

all stored

flights).

3.

Tap

STEP

and wait until

download progress bar
completes and normal display
returns.

4.

Remove USB Flash Drive.

Trip Mode (Accumulate Fuel
Used)

1.

Hold both

STEP

and

LF

until

the display shows

PROGRAM

,

followed by

Refuel ?

.

2.

Tap

NEXT

until you see

Trip

Used? No

.

3.

To accumulate all fuel used,
tap

Yes

and see

TRIP? Y

.

4.

Tap left button until you see

End ?Y

and tap

Yes

to exit.

Advertising