AEM Infinity Supported Applications - Toyota 1993-1997 Supra Turbo User Manual

Page 14

Advertising
background image

14

© 2014 AEM Performance Electronics

Infinity

Pin

Hardware Reference

7100-XXXX-62
7101-XXXX-63

Function

Hardware Specification

Notes

C1-67

Analog_In_Temp_2

Intake Air

Temperature

12 bit A/D, 2.49K pullup to 5V

See "Air Temperature" Setup Wizard f or
selection.

C1-68

Harness_Analog_In_Temp
_3

Oil Temperature

Sensor

12 bit A/D, 2.49K pullup to 5V

See 1D table OilTempCal table f or
calibration data and OilTemp [C] f or channel
data.

C1-69

Stepper_2A

Stepper 2A

Automotiv e, Programmable
Stepper Driv er, up to 28V and
±1.4A

Be sure that each internal coil of the
stepper motor are properly paired with the
1A/1B and 2A/2B ECU outputs. Supports Bi-
Polar stepper motors only .

C1-70

Stepper_1A

Stepper 1A

Automotiv e, Programmable
Stepper Driv er, up to 28V and
±1.4A

Be sure that each internal coil of the
stepper motor are properly paired with the
1A/1B and 2A/2B ECU outputs. Supports Bi-
Polar stepper motors only .

C1-71

Stepper_2B

Stepper 2B

Automotiv e, Programmable
Stepper Driv er, up to 28V and
±1.4A

Be sure that each internal coil of the
stepper motor are properly paired with the
1A/1B and 2A/2B ECU outputs. Supports Bi-
Polar stepper motors only .

C1-72

Stepper_1B

Stepper 1B

Automotiv e, Programmable
Stepper Driv er, up to 28V and
±1.4A

Be sure that each internal coil of the
stepper motor are properly paired with the
1A/1B and 2A/2B ECU outputs. Supports Bi-
Polar stepper motors only .

C1-73

Power Ground

Ground

Power Ground

Connect directly to battery ground.

C2-1

DBW2 Motor +

DBW Motor Control

Open

5.0A max Throttle Control Hbridge
Driv e

+12V to open

C2-2

DBW2 Motor -

DBW Motor Control

Close

5.0A max Throttle Control Hbridge
Driv e

+12V to close

C2-3

Power Ground

Ground

Power Ground

Connect directly to battery ground.

C2-4

Injector 7

Injector 7

Saturated or peak and hold, 3A
max continuous

Injector 7

C2-5

Injector 8

Injector 8

Saturated or peak and hold, 3A
max continuous

Injector 8

C2-6

Injector 9

Injector 9

Saturated or peak and hold, 3A
max continuous

Injector 9

C2-7

Injector 10

Injector 10

Saturated or peak and hold, 3A
max continuous

Injector 10

C2-8

Power Ground

Ground

Power Ground

Connect directly to battery ground.

C2-9

+12V

+12V In

12 v olt power f rom relay

12 v olt power f rom relay . Relay must be
controlled by +12V Relay Control signal, pin
C1-29 abov e.

C2-10

Injector 11

Injector 11

Saturated or peak and hold, 3A
max continuous

Not used

C2-11

Injector 12

Injector 12

Saturated or peak and hold, 3A
max continuous

Not used

C2-12

Analog_In_17

A/C Analog Request

12 bit A/D, 100K pullup to 5V

0–5V analog signal. Use +5V Out pins as
power supply and Sensor Ground pins as
the low ref erence. Do not connect signals
ref erenced to +12V as this can permanently
damage the ECU. See Setup Wizard Input
Functions page f or input selection. See
AC_Request_In 1-axis table f or activ ation
logic.

C2-13

Analog_In_18

DBW_APP1 [%]

12 bit A/D, 100K pullup to 5V

0–5V analog signal. Use +5V Out pins as
power supply and Sensor Ground pins as
the low ref erence. Do not connect signals
ref erenced to +12V as this can permanently
damage the ECU.

Advertising