NOTE:

Avoid mounting sensors in areas with a large quantity of metal or electrical wiring, such as a furnace or utility room.

To mount the sensor, do the following:

1

Place the base of the sensor in the desired location and secure with the included screws (as shown in the previous figure).

2

When mounting the magnet, line up the arrow on the magnet with the middle line on one side of the sensor (see figure on first page). 
Mount the magnet no more than 0.4 in. (1 cm) away from the sensor. Be sure to secure the magnet with adhesive.

For use with external input, do the following:

1

Repeat above instructions for mounting. Drill hole through access hole, if needed (as shown in the figure 
on the previous page).

2

Plug two‐pin connector into J1 (see figure).

3

Connect wire to N/C dry contact device.

Inserting and Replacing Batteries

If a supervised sensor battery is low, a low battery notification is indicated on the Control Panel. When the 
2GIG system indicates that the sensor has a low battery, replace the battery immediately. Use only the 
recommended replacement batteries (See Specifications). To install or replace the battery, do the following:

1

To remove the sensor cover, use your finger to press the tab on the end of the case. This disengages the 
clip holding the cover to the base.

2

Place a small flathead screwdriver in the slot between the metal clip and battery and twist the 
screwdriver slightly while holding back one of the black plastic edges holding the battery.

3

Insert the replacement battery with the + sign facing out.

4

Verify programming and RF communication with the Control Panel (see Testing).

WARNING:

The polarity of the battery must be observed, as shown. Improper handling of lithium 

batteries may result in heat generation, explosion or fire, resulting in personal injuries. Replace only with 
the same or equivalent type of battery as recommended by the manufacturer (see Specifications). 

Batteries must not be recharged, disassembled or disposed of in fire. Disposal of used batteries must be 
made in accordance with the waste recovery and recycling regulations in your area. Keep Away From 
Small Children. If batteries are swallowed, promptly seek medical attention. 

California Only: This Perchlorate warning applies only to Manganese Dioxide Lithium cells sold or distributed ONLY in /California, U.S.A. 
Perchlorate Material‐special handling may apply. See dtsc.ca.gov/hazardouswaste/perchlorate.

Specifications

FCC and Industry Canada Regulatory information

This device complies with Part 15 of the FCC's Rules. Operation is subject to the following two conditions:
1) This device may not cause harmful interference, and
2) This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These 
limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses 
and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to 
radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause 
harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to 
try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

This product complies with FCC radiation exposure limits for an uncontrolled environment. Avoid operating this product at a distance less than 
20 cm from the user.
Caution: Any changed or modifications not expressly approved by the party responsible for compliance could void the user's authority to 
operate this equipment.

LIMITED WARRANTY

This 2GIG Technologies product is warranted against defects in material and workmanship for 2 years. This warranty extends only to wholesale 
customers who buy direct from 2GIG Technologies or through 2GIG Technologies’ normal distribution channels. 2GIG Technologies does not 
warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if any.
There are no obligations or liabilities on the part of 2GIG Technologies for consequential damages arising out of or in connection with use or 
performance of this product or other indirect damages with respect to loss of property, revenue, or profit, or cost of removal, installation, or 
reinstallation. All implied warranties for functionality, are valid only until the warranty expires. This 2GIG Technologies Warranty is in lieu of all 
other warranties expressed or implied.

For technical support in the USA and Canada:

855-2GIG-TECH (855-244-4832)

For technical support outside of the USA and Canada:

Contact your regional distributor

Visit dealer.2gig.com for a list of distributors in your region.

PN: 187-0678 Rev C

2GIG Copyright © 2013. All rights reserved.

Wireless Signal Range

350 ft, open air, with 2GIG Wireless Control Panel

Code Outputs

Alarm; Alarm Restore; Supervisory; Low Battery; External Alarm; External Restore; Tamper; Tamper Restore

Transmitter Frequency

345.000 MHz (crystal controlled)

Transmitter Frequency Tolerance

±15kHz

Transmitter Bandwidth

24kHz

Modulation Type 

Amplitude Shift Keying‐On/Off Keying (ASK‐OOK)

Unique ID Codes

Over one million different code combinations

Supervisory Interval

70 minutes

Peak Field Strength

Typical 36,000 uV/m at 3m

External Input Sampling Current

20 uA

External Input

Accepts N/C dry contact devices

Reed Switch Magnetic Sensitivity

10 to 20 amp turns

Reed Sensitivity

0.625 in. (1.59 cm) minimum gap, 0.85 in. (2.16 cm) typical

Magnet Dimensions (LxWxH)

1.3 x 0.435 x 0.312 in. (3.3 x 1.1 x 0.79 cm) typical

Magnet Type

Rare earth

Sensor Dimensions (HxD)

2.59 x 1.03 x 0.49 in. (6.58 x 2.62 x 1.24 cm)

Weight (including battery and magnet)

1.1 oz. (31.2 g)

Housing Material

ABS plastic

Color

White

Operating Temperature Limits

32° to 120° F (0° to 49° C)

Relative Humidity

5‐95% Non‐Condensing

Battery (installed with pull tab)

Two Panasonic CR2032 or equivalent Lithium batteries

Included Accessories

Two Phillip’s flat‐head screws, one 2‐pin connector with a 12” flying wire lead, adhesive strip