Mounting the PIR with the bracket (see Figure 2)

1

Use short Phillips head screws to screw part A into part B.

2

Select either the corner mount (part C) or flat wall mount (part D).

3

Mount the selected bracket (C or D) at a height of 7.5 ft (2.3 m). on 
the wall using the supplied long screws with anchors.

4

Place the assembly of parts A and B on the shaft of bracket C or D.

5

Screw a Phillips head screw with washer into the top of par B to hold 
the assembly to the shaft of bracket C or D.

6

Attach the main body of the PIR to the mounted back with a screw at 
the bottom of the case.

Mounting the PIR without bracket (see Figure 3)

1

For corner mounting use the supplied long screws with anchors and 
mount the PIR case back using either the right two corner mount 
screw holes (A) or the left two corner mount screw holes and mount 
the PIR back at a height of 7.5 ft. (2.3 m). Attach the main body of the 
PIR to the mounted back with the screw at the bottom of the PIR.

2

For mounting the PIR on a flat wall use the 

supplied long screws with anchors and mount 
the PIR case back using the 2 wall mount screw 
holes in the center of the back and mount the 
back at a height of 7.5 ft. (2.3 m). Attach the 
main body of the PIR to the mounted back with 
the screw at the bottom of the PIR.

Using the PIR with Pets

To take full advantage of the pet immunity features, do the following:
1

Ensure that the PIR is mounted 7.5‐8 feet above floor level.

2

Set the right jumper (SENSITIVITY) to low (default).

3

Ensure that the left jumper (PET IMMUNITY) is set to your pet’s 
weight.

4

Do not aim the PIR at stairs or furniture that your pet could climb on.

NOTE: The PIR provides immunity to false alarms for an individual 

animal or a group of animals whose total weight is equal to or less 
than 55 pounds when the room temperature is above 50° F and 
below 90° F. If you used the optional mounting bracket, ensure that 
the PIR is mounted with NO tilt.

Environmental and other Useful Information

While the PIR is a highly reliable intrusion detection device, it does not 
guarantee against burglary. Any intrusion device is subject to a “failure to 
warn” for a variety of reasons. Consider the following when installing the PIR 
for the first time or when you are troubleshooting:
1

This PIR has built‐in protection, that keeps bugs from getting into the 
sensor area and causing false alarms. This does not prevent insects 
from crawling across the lens of the PIR, which could trigger the PIR.

2

Infrared energy can be reflected off any glossy surfaces such as 
mirrors, windows, floors or counter tops with glossy finish, and slick 
finished concrete. Some surfaces reflect less than others. For 
example, the PIR can see a change in infrared energy off of reflective 
surfaces even if the heat or cold source is not within the PIR detection 
pattern.

3

Windows cannot only reflect infrared energy, but they can also allow 
sunlight or lights from cars to pass through to the PIR. For example, a 
PIR can detect a quick change in infrared energy if sunlight comes 
through a window and shines on a hardwood floor. If the change in 
infrared energy is quick enough on the hardwood floor, the PIR can 
trigger an alarm. The same applies if the PIR area includes a window, 
even though the pattern of protection cannot “see” through glass. 
Lights from a passing car can also pass through the window at night 
and directly in the lens of the PIR.

4

Heating and air conditioning ducts are also important because if they 
blow air onto an object within the field of the PIR’s view, the 
temperature of that object could change quickly enough for the 
detector to “see” a change in infrared energy. PIR’s CANNOT see air 
current, only the change in temperature of a physical object.

5

The PIR senses change in temperature; however, as the ambient 
temperature of the protected area approaches the temperature 
range of 95° to 120° F, the detection performance of the PIR 
decreases.

6

Ensure that the area you wish the PIR to cover is free of obstructions 
(curtains, screens, plants, etc.) that may block the pattern of 
coverage.

7

Anything that can sway or move due to air current can cause a change 
in infrared energy within the fields of view. Drafts from doors or 
windows can cause this to happen. Plants, balloons, curtains and 
hanging baskets should never be left in the PIR’s field of view.

8

Do not mount the PIR on a surface that allows for any vibration. 
Vibrations not only cause the PIR to move a little, but it also causes 
the fields of view in a room to move with respect the PIR. A little 
vibration can cause havoc with the PIR’s field of view, thus the PIR 
may see a change in energy and trigger the alarm.

9

An installation often requires that the PIR is aimed at the door. The 
PIR may detect door movement before the door contact can initiate 
an entry delay, causing the alarm to trigger. If you install the PIR 
facing a door, then while programming the PIR, choose an entry delay.

10

The PIR ONLY detects intrusion within the pattern of coverage.

11

The PIR does not provide volumetric area protection.

12

The PIR creates multiple beams of protection. Intrusion can only be 
detected in unobstructed areas covered by those beams.

13

The PIR cannot detect motion or intrusion that occurs behind walls, 
ceilings, floors, closed doors, partitions, glass doors or windows.

14

Tampering with, masking, painting, or spraying of any material on the 
PIR lens or any part of the optical system can impair detection ability.

15

The PIR, like other electrical devices, are subject to component 
failure. Even though the PIR is designed to last as long as 10 years, the 
electronic components are subject to failure.

Specifications

FCC Compliance Statement*

Notice: Unauthorized changes or modifications could void the user’s authority to operate the 
equipment.
This device complies with Part 15 of the FCC Rules and Industry Canada license‐exempt RSS 
standard(s). Operating is subject to the following two conditions: (1) This device may not cause 
harmful interference, and (2) this device must accept any interference received, including 
interference that may cause undesired operation of the device

.

For technical support in the USA and Canada

855-2GIG-TECH (855-244-4832)

For technical support outside of the USA and Canada

Contact your regional distributor

Visit 2gig.com for a list of distributors in your region

PN 187-0727 Rev. F

A Corner mounting screw holes
B Flat wall mounting screw holes
C Bracket screw holes

Wireless Signal Range

350 ft., open air, with 2GIG Control Panel

Code Outputs

Alarm; Alarm Restore; Tamper; Tamper Restore; Supervisory; 
Low Battery

Transmitter Frequency

345,000 MHz (crystal controlled)

Transmitter Frequency Tolerance

±15 kHz

Transmitter Bandwidth

24 kHz

Modulation Type

Amplitude Shift Keying‐On/Off Keying (ASK‐OOK)

Unique ID Codes

Over 1 million different code combinations

Supervisory Interval

70 minutes

Peak Field Strength

Typical 50,000 uV/m at 3m

Sensor Type

Quad element

Pet immunity

Selectable: 15 kg (33 lbs) or 25 kg (55 lbs; default)

Sensitivity Jumper

Selectable: HIgh or Low (default)

Suggested Mounting Height

7.5 ft (2.3 m)

Sensor Range

30 ft. (9.1 m) x 50 ft. (15.2 m)

Max. Horizontal Sensing Angle

90°

Dimensions (LxWxH)

3.2 x 2.5 x 1.9 in. (8.12 x 6.35 x 4.82 cm)

Weight (inc. battery & bracket)

3.7 oz. (104.9 g)

Housing Material

ABS plastic and poly‐carbonate

Color

White

Operating Temperature

32° to 120° F (0° to 49°)

Relative Humidity

5‐95% Non‐Condensing

Battery (included, not installed)

1 Panasonic CR123A, or equivalent Lithium battery

Regulatory LIstings

ETL, FCC Part 15, Industry Canada

Warranty*

2 years

Included Accessories

Mounting brackets, 2 long Phillip’s head screws, 2 plastic wall 
anchors

Advertising