Important to remember, Specifications, Regulatory compliance – 2GIG TAKE-345 Super Switch User Manual

Page 4: Limited warranty, Specifications regulatory compliance

Advertising
background image

4

©2013 2GIG by Linear Corporation. All Rights Reserved.

Important to Remember

1

All of the zones on the Super Switch are “normally closed” zones.

2

The maximum loop resistance cannot exceed 3K ohms (If the loop resistance 
exceeds 3K ohms and the existing panel used end of line resistance, then the 
end of line resistor may be removed).

3

Different control panels have different terminals for each zone and aux power. 
Please refer to the wiring diagrams that came with the existing panels. For 
example, the HI side of Zone 1—Zone 8 on a “Vista” panel is typically terminals 
8,11,12,14,15,17,18, and 20. AUX positive is typically terminal 5 on a “Vista” 
panel.

WARNING:

The Super Switch CANNOT be used to monitor any type of fire 

or CO Detection Zones.

Specifications

Regulatory Compliance

This device complies with Part 15 of the FCC's Rules. Operation is 
subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including 
interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits 
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These 
limits are designed to provide reasonable protection against harmful 
interference in a residential installation.
This equipment generates, uses and can radiate radio frequency 
energy and, if not installed and used in accordance with the 
instructions, may cause harmful interference to radio 
communications. However, there is no guarantee that interference 
will not occur in a particular installation. If this equipment does cause 
harmful interference to radio or television reception, which can be 
determined by turning the equipment off and on, the user is 
encouraged to try to correct the interference by one or more of the 
following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from 
that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

This product complies with FCC radiation exposure limits for an 
uncontrolled environment. Avoid operating this product at a distance 
less than 20 cm from user.
Caution: Any changed or modifications not expressly approved by the 
party responsible for compliance could void the user's authority to 
operate this equipment.

Limited Warranty

This 2GIG Technologies product is warranted against defects in 
material and workmanship for 2 years. This warranty extends only to 
wholesale customers who buy direct from 2GIG Technologies or 
through 2GIG Technologies’ normal distribution channels. 2GIG 
Technologies does not warrant this product to consumers. Consumers 
should inquire from their selling dealer as to the nature of the dealer’s 
warranty, if any.
There are no obligations or liabilities on the part of 2GIG Technologies 
for consequential damages arising out of or in connection with use or 
performance of this product or other indirect damages with respect to 
loss of property, revenue, or profit, or cost of removal, installation, or 
reinstallation. All implied warranties for functionality, are valid only 
until the warranty expires. This 2GIG Technologies Warranty is in lieu 
of all other warranties expressed or implied.

For technical support in the USA and Canada:

855‐2GIG‐TECH (855‐244‐4832)

Email: [email protected]

Internet: dealer.2gig.com
Visit web site for technical support hours of operation

For technical support outside of the USA and Canada:

Contact your regional distributor

Visit dealer.2gig.com for a list of distributors in your region

PN: 77‐000009‐001

Wireless Signal Range

350 ft, open air, with 2GIG Wireless Control Panel

Code Outputs

For each of 8 serialized zones: Fault; Restore; 
Tamper; Low Battery

Transmitter Frequency

345.000 MHz (crystal controlled)

Transmitter Frequency 
Tolerance

±15kHz

Transmitter Bandwidth

24kHz

Modulation Type 

Amplitude Shift Keying‐On/Off Keying (ASK‐OOK)

Unique ID Codes

Over one million different code combinations

Supervisory Interval

70 minutes

Peak Field Strength

Typical 50,000 uV/m at 3m

Sensor Dimensions (LxWxH)

3.54 x 2.56 x 1.13 in. (9.0 x 6.5 x 2.9 cm)

Weight (including bracket)

2.85 oz. (80.8 g)

Housing Material

ABS plastic

Color

White

Operating Temperature Limits 32° to 120° F (0° to 49° C)
Relative Humidity

5‐95% Non‐Condensing

Operating Voltage

9‐16 volts DC, 50mA

Included Accessories

Mounting plate, 2 Phillip’s head screws, 2 plastic 
drywall anchors

Advertising