Conditions resulting in dangerous co situations, Replacing the detector, Carbon monoxide gas and its detection – 2GIG CO3-345 Carbon Monoxide Detector User Manual

Page 3: Specifications regulatory compliance

Advertising
background image

©2013 2GIG by Linear Corporation. All Rights Reserved.

3

Carbon Monoxide Gas and its Detection

This carbon monoxide detector is designed for indoor use only. Do not expose to 
rain or moisture. Do not knock or drop the detector. Do not open or tamper with 
the detector as this could cause malfunction. The detector will not protect against 
the risk of carbon monoxide poisoning if not properly installed.

WARNING:

This device will only indicate the presence of carbon monoxide 

gas at the sensor. Carbon monoxide gas may be present in other areas.

This carbon monoxide alarming device is designed to detect carbon monoxide gas 
from ANY source of combustion. It is NOT designed to detect smoke, or other gases 
unless the product has been investigated and determined to comply with applicable 
requirements.
This device should not be installed as a substitute for proper installation, use, and 
maintenance of fuel burning appliances, including appropriate ventilation and 
exhaust systems.
Carbon monoxide gas is a highly poisonous gas which is released when fuels are 
burned. It is invisible, has no smell and is therefore impossible to detect with the 
human senses. Under normal conditions in a room where fuel burning appliances 
are well maintained and correctly ventilated, the amount of carbon monoxide 
released into the room by appliances should not be dangerous.

Conditions Resulting in Dangerous CO
Situations

1

Excessive spillage or reverse venting of fuel‐burning appliances caused by:

outdoor ambient conditions, such as wind direction and/or velocity, 
including high gusts of wind, and insufficient draft in the vent pipes

negative pressure differential resulting from the use of exhaust fans

simultaneous operation of several fuel‐burning appliances competing for 
limited internal air

loose vent pipe connections from fuel‐fed appliances,

obstructions, or unconventional vent pipe designs that can amplify the 
above situations

poorly designed or maintained chimneys and/or vents

2

Extended operation of unvented fuel‐burning devices (range, oven, replace, 
etc.)

3

Temperature inversions that trap exhaust gases near the ground

4

Car idling in an open or closed attached garage, or near a home

If you have been exposed to Carbon Monoxide Poisoning, you may be suffering 
from various symptoms (discuss these symptoms with all of the members of your 
household):

Mild Exposure

Headache, running nose, sore eyes (often described as ‘flu‐like’ symptoms)

Medium Exposure

Dizziness, drowsiness, vomiting

Extreme Exposure

Unconsciousness, brain damage, death

Many reported cases of reported Carbon Monoxide Poisoning indicate that while 
victims are aware they are not well, they become so disoriented that they are 
unable to save themselves by either exiting the building or calling for assistance.
Young children and pets may be the first to be affected.

WARNING:

Individuals with medical problems should consider using 

warning devices which provide audible and visual signals for carbon 
monoxide concentrations under 30 ppm.

Actuation of this device indicates the presence of Carbon
Monoxide (CO) which can KILL YOU

If the alarm signal sounds, four beeps:

1

Push the hush/test button.

2

Immediately move to fresh air (outdoors or next to an open window).

3

Check that all persons within the area are accounted for.

4

Do not re‐enter the premises (or move away from the open window until the 
emergency service responders have arrived, the premises have been aired out, 
and your alarm remains in normal condition.

5

Call emergency services, the fire department, or 911.

6

If the service signal sounds, one chirp, then check the service section to try and 
correct.

7

After following steps 1‐6, if your alarm reactivates within a 24‐hour period, 
repeat steps 1‐6 and call your local qualified technician to investigate for 
sources of CO from fuel burning equipment and appliances and inspect for 
proper operation of this CO detector. If problems are identified during this 
inspection, have the equipment serviced or replaced immediately. Note any 
combustion equipment not inspected by the technician and consult the 
manufacturer’s instructions, or contact the manufacturers directly for more 
information about CO safety and this equipment. Make sure that motor 
vehicles are not, and have not been, operating in an attached garage or 
adjacent to the residence. 

Replacing the Detector

This detector is manufactured with a long‐life carbon monoxide sensor. Over time 
the sensor will lose sensitivity, and will need to be replaced with a new carbon 
monoxide detector. The detector’s lifespan is 5 years from the date of manufacture. 

NOTE:

When the detector is removed from its base, a Tamper message is 

sent to the central monitoring station. The detector also causes a trouble 
condition when it has reached the end of its life. If this occurs, it is time to 
replace the detector. 

Before replacing the detector, notify the central monitoring station that 
maintenance is being performed and that the system will be temporarily out of 
service. From the Control Panel, disable the zone or system undergoing 
maintenance to prevent any unwanted alarms. Dispose of the detector in 
accordance with any local regulations.

IMPORTANT:

The Replacement Date that appears on the device is the date 

beyond which the device may no longer detect carbon monoxide 
accurately and should be immediately replaced.

The installation, operation testing and maintenance of the Wireless Carbon 
Monoxide Alarm is different than smoke detectors. Per NFPA 720 section 5.3.7.2 the 
detector shall not be connected to a zone that signals a fire condition (i.e. smoke 
detector/alarm zones). Therefore, the Wireless Carbon Monoxide Alarm must be 
programmed as a non‐fire zone. See step 2 under Programming for the correct 
Carbon Monoxide zone type to program.

Specifications

Regulatory Compliance

This device complies with Part 15 of the FCC's Rules. Operation is subject to the 
following two conditions:

1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may 
cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B 
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to 

provide reasonable protection against harmful interference in a residential 
installation.

This equipment generates, uses and can radiate radio frequency energy and, if not 

installed and used in accordance with the instructions, may cause harmful 
interference to radio communications. However, there is no guarantee that 

interference will not occur in a particular installation. If this equipment does cause 
harmful interference to radio or television reception, which can be determined by 
turning the equipment off and on, the user is encouraged to try to correct the 
interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which 
the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

This product complies with FCC radiation exposure limits for an uncontrolled 
environment. Avoid operating this product at a distance less than 20 cm from user.
Caution: Any changed or modifications not expressly approved by the party 
responsible for compliance could void the user's authority to operate this 
equipment.

Limited Warranty

This 2GIG Technologies product is warranted against defects in material and 
workmanship for 2 years. This warranty extends only to wholesale customers who 

buy direct from 2GIG Technologies or through 2GIG Technologies’ normal 
distribution channels. 2GIG Technologies does not warrant this product to 
consumers. Consumers should inquire from their selling dealer as to the nature of 

the dealer’s warranty, if any.
There are no obligations or liabilities on the part of 2GIG Technologies for 
consequential damages arising out of or in connection with use or performance of 

this product or other indirect damages with respect to loss of property, revenue, or 

profit, or cost of removal, installation, or reinstallation. All implied warranties for 
functionality, are valid only until the warranty expires. This 2GIG Technologies 

Warranty is in lieu of all other warranties expressed or implied.

For technical support in the USA and Canada:
855‐2GIG‐TECH (855‐244‐4832)
Email: [email protected]
Internet: dealer.2gig.com
Visit web site for technical support hours of operation

For technical support outside of the USA and Canada:
Contact your regional distributor
Visit dealer.2gig.com for a list of distributors in your region

PN: 39214‐596 Rev. B

Power Source

One 3‐volt CR123A Panasonic Lithium battery

Audible Signal (temp 4 tone)

85 dBA min. in alarm at 10 ft. (3m)

Operating Current

10 µA

Temperature Range

40° F (4.4° C) to 100° F (37.8° C)

Operating Humidity Range

15% to 95% Relative Humidity, non‐condensing

Agency Listings

UL Standard 2075, UL 2034 and CSA 6.19‐01