3 limit switch functional check, 3 limit switch functional check -6 – JLG 660SJ Operator Manual User Manual

Page 26

Advertising
background image

SECTION 2 - USER RESPONSIBILITIES, MACHINE PREPARATION, AND INSPECTION

2-6

– JLG Lift –

3121297

2.3 LIMIT SWITCH FUNCTIONAL CHECK

TO AVOID COLLISION AND INJURY IF PLATFORM DOES NOT STOP
WHEN A CONTROL SWITCH OR LEVER IS RELEASED, REMOVE FOOT
FROM FOOTSWITCH OR USE EMERGENCY STOP TO STOP THE
MACHINE.

NOTE: Perform checks from ground controls first, then from plat-

form controls.

1. Operate machine from ground control.

NOTE: For adjustments see Service Manual - Limit Switch Adjust-

ments.

2. Check elevation limit switch as follows:

a. Lift boom up to 2 degrees to 7 degrees above hori-

zontal. The switch should activate at this point.

b. Lift boom down to 2.5 degrees to 7.5 degrees

below horizontal. The switch should reset at this
point.

3. Raise main boom, extend and retract telescope. Check

for delayed movement of fly section, indicating loose
cables.

4. Swing turntable to LEFT and RIGHT a minimum of 45

degrees. Check for smooth motion.

5. Check the chassis out of level indicator located on the

platform control console by driving, with the machine in
level position, up a suitable ramp of at least 5° slope.
Check the out of level indicator, with the machine on the
ramp. If the light does not illuminate, return the machine
to a level surface, shut down the machine, and contact a
qualified technician before resuming operation.

NOTE: Steps 6 & 7 cover 600S ANSI market machines with dual

capacities (500 & 1000 lb. [227 kg for ANSI markets and
230 kg for CE and Australia markets & 454 kg for ANSI
markets and 450 kg for CE and Australia markets]).

6. Check capacity limit switch as follows:

Boom Length Switch.

a. Raise boom to horizontal (place angle indicator on

base boom between boom pivot pin and lift cylinder
attach pin).

Advertising