SECTION 6 - DIAGNOSTIC TROUBLE CODES

6-6

– JLG Lift –

3121273

223

FUNCTION PROBLEM -
DRIVE & LIFT ACTIVE
TOGETHER

The Drive - Lift Selector Switch indi-
cates that both functions are selected
simultaneously

• Check drive/lift switch for visible damage.
• Check switch continuity. There should only be continuity from the

center post to one of the outer posts at a time. Otherwise, replace
the switch.

• Check drive/lift switch signal and wiring to the ground module.

"Lift" selection output (24V when selected) is terminal J2-3.
"Drive" selection output (24V when closed) is terminal J2-13.

• Replace platform board.
• HEALTH (Status LED) - ON

224

FUNCTION PROBLEM -
STEER LEFT PERMANENTLY
SELECTED

The steer left switch was closed during
power-up in platform mode.

• Check if the steer left switch is obstructed or jammed.
• Check steer left switch and its wiring, its output (24V when

closed) is to terminal J2-4.

• Replace platform board.
• HEALTH (Status LED) - ON

225

FUNCTION PROBLEM -
STEER RIGHT PERMA-
NENTLY SELECTED

The steer right switch was closed dur-
ing power-up in platform mode.

• Check if the steer right switch is obstructed or jammed.
• Check steer right switch and its wiring, its output (24V when

closed) is to terminal J2-12.

• HEALTH (Status LED) - ON

226

ACCELERATOR FAULTY -
WIPER OUT OF RANGE

The joystick (accelerator) wiper signal
input is outside the acceptable voltage
range.

• Center joystick and check to see if a power cycle will clear DTC.
• The wiper wire may be off, shorted to +B, or shorted to -B

(ground) to cause this difficulty.

• Check voltage on MS35 connector pins - A - 5V, B - 0.5 to 4.5V,

and C - 0V.

• HEALTH (Status LED) - ON

227

STEER SWITCHES FAULTY

Both the Steer Left and Steer Right
Inputs are closed as the same time.

• Check if the steer switches are damaged, obstructed or jammed.
• A short in the Steer Switch wiring or a failed Steer Switch can

cause this difficulty.

• Check the steer switch signals and wiring outputs (24V when

closed) to terminals J2-4 and J2-12 (left and right).

• HEALTH (Status LED) - ON

228

FUNCTION LOCKED OUT -
ACCELERATOR NOT CEN-
TERED

Selected function (Drive or Lift) is not
allowed because the joystick (accelera-
tor) was not centered at power-up.

• Release joystick and allow to center.
• Check if the joystick is obstructed or jammed.
• Check the joystick signal and its wiring.
• Check voltage at MS35.
• HEALTH (Status LED) - ON

229

FUNCTION PROBLEM - TRIG-
GER PERMANENTLY
CLOSED

Trigger Switch in the Platform Control
Box was closed at power-up.

• Check if the trigger switch is obstructed or jammed.
• Release switch or repair the switch / wiring to clear the difficulty.
• Check the trigger switch signal and wiring. The trigger input (24V

when closed) is to terminal J2-10.

• HEALTH (Status LED) - ON

2210

TRIGGER CLOSED TOO LONG
WHILE IN NEUTRAL

Trigger Switch in the Platform Control
Box was closed for more than five sec-
onds while the Joystick (accelerator)
was in the neutral position (centered)

• Release switch or repair the switch / wiring to clear the difficulty.
• Check if the trigger switch is obstructed or jammed.
• Check the trigger switch signal and wiring. The trigger input (24V

when closed) is to terminal J2-10.

• HEALTH (Status LED) - ON

2232

FUNCTION PROBLEM -
DRIVE & LIFT BOTH OPEN

In Platform Mode, the Drive - Lift Selec-
tor Switch indicates that neither func-
tion is selected.

• Repair the wiring or switch to clear the message.
• Check if either function is active, if Yes;
• HEALTH (Status LED) - ON