SECTION 6 - DIAGNOSTIC TROUBLE CODES

3121273

– JLG Lift –

6-13

4422

LOGIC SUPPLY VOLTAGE
OUT OF RANGE

The system module logic supply volt-
age was measured by the power PCB to
be less than 11V for 10uS.

• This may be caused by a loose battery terminal, severely dis-

charged batteries, damaged battery, or an improper wire harness
connection.

• Drive, Steer, and Lift Prevented
• HEALTH (Status LED) - ON

6-6 Communication

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

661

CANBUS FAILURE - POWER
MODULE

The control system failed to receive
messages from the power micropro-
cessor.

• This may occur if re-programming was interrupted.
• Alternately, this may be an internal fault.
• HEALTH (Status LED) - ON

6643

CANBUS FAILURE - LSS
ANGLE SENSOR

The control system failed to receive
messages from the angle sensor.

• Check wiring to the Angle Sensor.
• HEALTH (Status LED) - ON

7-7 Electric Motor

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

772

STALLED TRACTION MOTOR
OR POWER WIRING ERROR

The System Module detected armature
current feedback > 4.5V or < 0.5V.

• This is mostly likely caused by a stalled traction motor or power

wiring issue. Alternately, it could be an internal fault.

• HEALTH (Status LED) - ON

773

CAPACITOR BANK FAULT -
CHECK POWER CIRCUITS

There is an internal or external fault that
prevents the System Module’s capaci-
tor bank from charging.

• The System Module detected that the VMN of the pump and trac-

tion has not increased more than 1.3V in 1000mS. Alternately,
the VMN of the pump or traction is less than 20% of battery volt-
age.

• If this message persists after disconnecting the drive and pump

wiring, there is an internal fault.

• HEALTH (Status LED) - ON

774

SHORT CIRCUIT - FIELD
WIRING

The field wiring passed System Module
power-up diagnostics. However, an
external short circuit was detected
when current was applied to F1 / F2.

• This situation is caused by improper field wiring or a damaged

motor.

• HEALTH (Status LED) - ON

775

OPEN CIRCUIT - FIELD WIR-
ING

The System Module applied field cur-
rent, but could regulate the desired cur-
rent.

• The situation is caused by improper field wiring or a damaged

motor.

• HEALTH (Status LED) - ON

776

STALLED PUMP MOTOR OR
POWER WIRING ERROR

The System Module measured
improper pump current feedback
(>4.5V or <0.5V) for 240mS.

• This is caused by a stalled pump motor, a power wiring issue, or

a System Module malfunction.

• HEALTH (Status LED) - ON

777

OPEN CIRCUIT PUMP
MOTOR WIRING

This indicates there is an open-circuit
between the System Module’s –P ter-
minal and the pump motor.

• The System Module measured pump current less than 8A while

the motor voltage was greater than 7V for 1200mS.

• HEALTH (Status LED) - ON

778

TRACTION T HIGH - CHECK
POWER CIRCUITS

While driving, the voltage measured at
the System Module’s T-terminal did not
agree with the predicted value.

• This issue may be caused by a power wiring error or an internal

fault.

• HEALTH (Status LED) - ON

4-4 Battery Supply

DTC

FAULT MESSAGE

DESCRIPTION

CHECK