SECTION 3 - USER RESPONSIBILITIES AND MACHINE CONTROL

3-12

– JLG Lift –

3120748

20.

Soft Touch Indicator. (If Equipped)

When illuminated (Yellow) the Soft Touch bumper is
against an object. All controls are cut out until the
override button is pushed, at which time controls are
active in the Creep mode.

21.

AC Generator. (Green)

When illuminated (Green), the light indicates the
generator is in operation.

22.

Low Fuel Indicator. (Yellow)

When illuminated (Yellow), the fuel tank is 1/8 full or
less. When the light first turns on, there are approxi-
mately four usable gallons of fuel remaining.

23.

Auxiliary Power.

A toggle-type Auxiliary Power control switch ener-
gizes the electrically operated hydraulic pump,
when actuated. (Switch must be held ON for dura-
tion of auxiliary pump use.)

The auxiliary pump functions to provide sufficient oil
flow to operate the basic machine functions should
the main pump or engine fail. The auxiliary pump will
operate tower boom lift, tower telescope, main
boom lift, main telescope and swing.

It should be noted that the functions will operate at a
slower than normal rate because of the lower gpm
delivered.

WHEN OPERATING ON AUXILIARY POWER, DO NOT OPERATE
MORE THAN ONE FUNCTION AT THE SAME TIME. SIMULTA-
NEOUS OPERATION CAN OVERLOAD THE AUXILIARY PUMP
MOTOR.

NOTE: The main function of auxiliary power is to lower the

platform in the event of primary power failure. Deter-
mine the reason for primary power failure and have
the problem corrected by a certified JLG service
technician. Operate as follows:

a. Position Platform/Ground switch to Platform.

b. Position Power/Emergency Stop switch to the

on position.

c. Depress and hold footswitch.

d. Operate appropriate control switch or lever for

desired function and hold.

e. Position Auxiliary Power switch to the on posi-

tion and hold.

f.

Release Auxiliary Power switch, selected control
switch or lever, and footswitch.

g. Position Power/Emergency Stop switch to the off

position.

3.5

PLACARDS AND DECALS

Read and understand all placards and decals. Do not
operate any machine on which DANGER, WARNING,
CAUTION OR INSTRUCTION PLACARDS OR DECALS
ARE MISSING OR ILLEGIBLE. Replace placards and
decals if damaged, missing or illegible.

Decals are made of Lexan Pressure Sensitive Adhesive
with a protective film on the front. Remove the damaged
decal and thoroughly clean surface before installing a new
decal. Simply peel off the back, and press new decal onto
surface.

NOTE: Placards and Decals can be ordered by using part

numbers located by each placard or decal. (See Fig-
ure 3-7. Danger and Warning Decal Location.)