Changing from lp gas to gasoline, 10 shut down and park, Shut down and park – JLG 340AJ Operator Manual User Manual

Page 59: Changing from lp gas to gasoline -11, 9 shut down and park -11, Shut down and park -11, 10 shut down and park shut down and park

Advertising
background image

SECTION 4 - MACHINE OPERATION

3121258

– JLG Lift –

4-11

Changing From LP Gas to Gasoline

1. With engine operating on LP under a no-load condition,

position FUEL SELECT switch at Platform Control Sta-
tion to GASOLINE position.

2. Close hand valve on LP gas supply tank by turning

clockwise.

4.10 SHUT DOWN AND PARK

Shut Down and Park

See Figure 4-4.

The procedures to shut down and park the machine are as
follows:

1. Drive machine to a reasonably well protected area.

2. Ensure boom is lowered over rear drive axle.

3. Shut down Emergency Stop at Platform Controls.

4. Shut down Emergency Stop at Ground Controls. Posi-

tion Platform/Ground Select switch to center OFF.

5. If necessary, cover Platform Controls to protect instruc-

tion placards, warning decals, and operating controls
from hostile environment.

Advertising