Changing from lp gas to gasoline, 10 shut down and park, Shut down and park – JLG 340AJ Operator Manual User Manual
Page 59: Changing from lp gas to gasoline -11, 9 shut down and park -11, Shut down and park -11, 10 shut down and park shut down and park
SECTION 4 - MACHINE OPERATION
3121258
– JLG Lift –
4-11
Changing From LP Gas to Gasoline
1. With engine operating on LP under a no-load condition,
position FUEL SELECT switch at Platform Control Sta-
tion to GASOLINE position.
2. Close hand valve on LP gas supply tank by turning
clockwise.
4.10 SHUT DOWN AND PARK
Shut Down and Park
See Figure 4-4.
The procedures to shut down and park the machine are as
follows:
1. Drive machine to a reasonably well protected area.
2. Ensure boom is lowered over rear drive axle.
3. Shut down Emergency Stop at Platform Controls.
4. Shut down Emergency Stop at Ground Controls. Posi-
tion Platform/Ground Select switch to center OFF.
5. If necessary, cover Platform Controls to protect instruc-
tion placards, warning decals, and operating controls
from hostile environment.