4 lsi-can check pt, Lsi-can check pt, Section – JLG 723A Service Manual User Manual

Page 155: 4, “lsi-can check pt

Advertising
background image

9.47

L2906H, 2906H, 3507H, 619A, 723A, 29.6LP, 29.6, 35.7

Electrical System

1. With the estimated test weight on the forks, start the

machine and extend the boom horizontally until the
machine starts to tip. This point should be at an
extension of Xtip (1) of the second boom section. If
the machine is not tipping at this extension, weight
needs to be added or removed from the forks.

2. By confirming that the machine tips at this point, the

correct amount of weight is now on the forks.

3. The machine control system must be powered on for

at least 10 minutes before calibration.

4. The machine must be on a level surface with the

wheels steered straight and park brake OFF. Drive
the machine forward over a distance of at least 2 m
(6.5 ft) before entering a calibration point.

5. Lower outriggers (if equipped), place test weight on

ground, apply park brake and shut engine OFF. Do
Not move machine.

Field Calibration Procedure:

Note: The following procedure must be completed
within 30 minutes of starting the procedure.

1. With ignition key in OFF position, press and hold

SYSTEM CHECK button on LSI display and turn
ignition key to engine START position. Release the
ignition key when engine start is achieved, but
continue to hold SYSTEM CHECK button on LSI
display until the orange LED on LSI display goes out
and buzzer sounds (approximately 3 seconds).
Release SYSTEM CHECK button.

2. The LEDs will perform a sequence. When only the

third green LED illuminates, press the SYSTEM
CHECK button.

3. The first green LED then illuminates. With no

attachment, outriggers down (if equipped), and
boom fully retracted, lift boom to maximum boom
angle.

4. Press the SYSTEM CHECK button on the LSI

display and release. The first 3 green LEDs will
illuminate. The third then second green LEDs will go
out as the calibration point is recorded.

5. The first green LED goes out and buzzer sounds

then the red LED illuminates.

6. Lower boom and without moving the machine, pick

up the proper test weight (W) listed in the table.
Pressing the LMI Override button may be required to
lower the boom.

7. With the boom horizontal, slowly extend the boom to

the distance of Xcal (2). The proper calibration
weight is now on the rear axle and the LSI can now
be calibrated.

8. Press the SYSTEM CHECK button on the LSI

display and release. As the calibration point is
recorded, buzzer sounds and the LEDs will flash and
perform a sequence until all are flashing.

9. Turn the ignition key to OFF. LSI is now calibrated.

10. Perform the LSI-CAN PT Check. Refer to Section

9.16.4, “LSI-CAN Check PT.”

Note: The following procedure MUST be performed
before the calibration is finalized.

9.16.4

LSI-CAN Check PT

With the LSI calibrated, the UGM also need it’s “LSI_CAN
CHECK PT” calibrated and verified.

1. Start the machine.

2. Press the “C” and “OK” buttons simultaneously on

the keypad or the analyzer.

3. Go to “ACCESS LEVEL 3” and press “OK”.

4. Enter the proper access code and press “OK”.

5. “ACCESS LEVEL 2 is now visible.

6. Go to “CALIBRATIONS” menu, press “OK”.

7. Scroll to “LSI_CAN CHECK PT”.

8. “SET LSI_CAN CHECK POINT”, use the arrow keys

to change “NO” to “YES”.

9. Follow the screen instructions:

a. “Remove Weights and Attachments”, press “OK”.

b. “TELESCOPE IN and FULLY LIFT UP”, press

“OK”.

c. “STOP, WAIT ONE MINUTE”, press “OK”.

d. “PRESS ENTER TO SET CHECK POINT”, press

“OK”

e. Screen defaults back to Calibrations Menu.

MZ5990

1

L2906H, 2906H, 3507H, 29.6LP, 29.6 & 35.7

MZ5990

2