SECTION 6 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE
3121179
– JLG Lift –
6-33
13. Oil Change w/Filter - Perkins
Lube Point(s) - Fill Cap/Spin-on Element (JLG P/N
7026855)
Capacity - 10 Quarts (9.4 L)
Lube - EO
Interval - Every Year or 500 hours of operation
Comments - Check level daily/Change in accordance
with engine manual.
14. Fuel Filter - Ford
Lube Point(s) - Replaceable Element
Interval - Every Year or 1200 hours of operation