Table 1 - Model Guide

Beckett

GeniSys

24V Control

Part No.

Lockout

Time

Valve-on

delay

time

1

Motor-

off

delay

time

1

7559A 0000

1

15 sec

0 sec

0 sec

7559P 1530

1

15 sec

15 sec

30 sec

7559P 152M

1

15 sec

15 sec

2 min

7559P 158M

1

15 sec

15 sec

8 min

1

Valve-on delay and motor-off delay timings on all models are

programmable with the Beckett Contractor Tool. Other factory

set timings are available. Contact Beckett for alternate

timings.

Features

Welded Relay Protection

Limited Relight

Valve-On Delay / Motor-Off Delay (Field

programmable with Beckett’s Contractor Tool)

15 Second Lockout Time

Interrupted Ignition

Communication Port

Lockout Alarm Output

Fused Protection


Specifications

Electrical Ratings

Inputs:

Voltage: 24 Vdc nominal (21.6 to 30 Vdc)
Current: 220 mA nominal (230 mA max at 30 Vdc)*
Enable Load: 22mA at 24 Vdc

Outputs:

Motor: 24 Vdc, 10 full load amps (FLA), 50 locked rotor
amps (LRA)
Igniter: 24 Vdc, 3 A
Solenoid Valve: 24 Vdc, 1 A
Lockout Alarm: 24 Vdc, 1A



Do Not Use This Control

in an Application that

is Not Within the Ratings Listed in This

Section. Improper Control Operation May

Result.

Do Not Use This Control

Above 5.5 GPH

CAUTION

A low or erratic power supply could

result in impaired burner operation,

severe delayed ignition or an explosion

inside the heat exchanger resulting in a

burn and/or asphyxiation hazard.

Maintain Specifi ed

Voltage

Beckett DC Burners require a

continuous supply of 21.6 to 30 volts

DC (at 11 amps for Model ADC or 15

amps for Model SDC), measured at

the burner during operation.
Consult other DC burner

manufacturers’ specifi cations for the

correct voltage range.
Special Note: The 7559 Control

shuts the burner down if the input

voltage drops to a sustained level

of 20 volts DC, or below. Operation

resumes at a sustained input

voltage of 21 volts DC, or above.
An automotive or small engine

charging system that is capable of

supplying the required continuous

voltage/amperage is recommended

with certain road equipment, such

as asphalt hot patchers and similar

applications.
This is especially true while

maintaining nominal load temperatures

during idle periods.

y

y

y

y

y

WARNING

CAUTION

Environmental Ratings:

Storage and Operating Ambient Temperature:
-40°F to +160°F (-40°C to +71°C)
Moisture: 5 to 95% RH, condensing


The 7559 control draws

40-55mA in the standby

state. If the red control wire is left powered

without a battery charging system, it can

drain a standard 45 Amp hour automotive

battery in four to six weeks.

NOTICE

*