Port locations and gauge installation, Port locations and gauge installation -56, Port locations -56 – JLG 340AJ Service Manual User Manual
Page 214: Port information -56
Advertising

SECTION 5 - HYDRAULICS
5-56
– JLG Lift –
3121259
Port Locations and Gauge Installation
PORT LOCATIONS AND GAUGE INSTALLATION
The following table and drawing show the port locations and
gauge sizes needed. When testing system pressures, calibrate
pressure gauges frequently to ensure accuracy. Use snubbers
to protect gauges.
Table 5-7. Port information
Port identifier
Port size
Wrench size
Pressure obtained
Gauge size, bar [psi]
L1,L2
1 1/16-12 UNF28
9/16 internal hex
Case drain
10bar[100psi]
MA, MB
9/16-18 UNF
1/4 internal hex
System pressure
600 bar [10,000 psi]
M3
9/16-18 UNF 2B
1/4 internal hex
Charge pressure
50 bar [1000 psi]
M4,M5
7/16-20 UNF 2B
3/16 internal hex
Servo pressure
50 bar [1000 psi]
Figure 5-31. Port Locations
Advertising