background image

SECTION 5 - HYDRAULICS

5-56

– JLG Lift –

3121259

Port Locations and Gauge Installation

PORT LOCATIONS AND GAUGE INSTALLATION

The following table and drawing show the port locations and
gauge sizes needed. When testing system pressures, calibrate

pressure gauges frequently to ensure accuracy. Use snubbers
to protect gauges.

Table 5-7. Port information

Port identifier

Port size

Wrench size

Pressure obtained

Gauge size, bar [psi]

L1,L2

1 1/16-12 UNF28

9/16 internal hex

Case drain

10bar[100psi]

MA, MB

9/16-18 UNF

1/4 internal hex

System pressure

600 bar [10,000 psi]

M3

9/16-18 UNF 2B

1/4 internal hex

Charge pressure

50 bar [1000 psi]

M4,M5

7/16-20 UNF 2B

3/16 internal hex

Servo pressure

50 bar [1000 psi]

Figure 5-31. Port Locations

Advertising