4 amp connector, Assembly, Amp connector -7 – JLG 340AJ Service Manual User Manual
Page 321: Assembly -7, Connector assembly figure 1 -7, 4 amp connector assembly

SECTION 7 - BASIC ELECTRICAL INFORMATION & SCHEMATICS
3121259
– JLG Lift –
7-7
MIL-C-5015 SPEC CONNECTORS
Crown Connector Inc's recommendation is to not use dielec-
tric grease for this series connector. For similar model series
connectors, the manufacturer should be contacted for confir-
mation before applying dielectric grease. A typical application
for this connector is on David Clark Intercom connections in
Aerial Work Platforms.
7.4
AMP CONNECTOR
Assembly
Check to be sure the wedge lock is in the open, or as-shipped,
position (See Figure 7-7.). Proceed as follows:
1.
To insert a contact, push it straight into the appropriate
circuit cavity as far as it will go (See Figure 7-9.).
2.
Pull back on the contact wire with a force of 1 or 2 lbs. to
be sure the retention fingers are holding the contact
(See Figure 7-9.).
Figure 7-7. Connector Assembly Figure 1
Figure 7-8. AMP Connector