3.16 GENERATOR
Every 250 hours
Every 250 hours of operation, check the drive belt for
proper tension.
Every 500 hours
Every 500 hours of operation, service the generator
brushes and slip rings. Hostile environments may require
more frequent service.
Every 500 hours of service, blow out the inside of the gen-
erator. If operating in a hostile environment, clean
monthly.
Table 3-8. Coupling Port Information Table
Port
No.
Outlets
Port Size
Description
Operating
Pressure
PSI (Bar)
Proof
Pressure
PSI (Bar)
1
2
-6
Brake
250 (17)
375 (26)
2
2
-6
2 Speed
4500 (310) 6750 (465)
3
1
-6
Steer
2000 (138) 3000 (207)
4
1
-6
Steer
2000 (138) 3000 (207)
5
3
2-16, 1-6
Drive Reverse
4500 (310) 6750 (465)
6
1
-16
Drive Forward
4500 (310) 6750 (465)
7
2
-12
Drain
250 (17)
375 (26)
1/2 in.