Load Stability Indicator (LSI)

8, 9, 12 & 13M Before S/N 1160005993 excluding 1160005949 & 1160005950
17M Before S/N 1160005937 including 1160005952, 1160005960, 1160005963,
1160005966 & 1160005978

The LSI (1) provides visual and audible indication of forward stability limitations
when machine is static on firm, level surface.

• Green LED (2) will illuminate when LSI power is on.

• When approaching forward stability limitations LEDs progressively illuminate,

green (3), then yellow (4) and finally red (5).

• The warning buzzer sounds as the first red LED illuminates.

• As the telehandler reaches forward stability limitations and the second red LED

illuminates, the automatic function cut-out is activated. Certain functions are
disabled (i.e. boom lift, extend, etc). Retract boom to re-enable functions.

• Press button (6) to disable the warning buzzer. When disabled, yellow LED (7)

will illuminate. If last red LED illuminates, disable button is overridden and
warning buzzer sounds.

• Test LSI (8) at the beginning of each work shift. See Section 8 - Additional

Checks.

WARNING

TIP OVER HAZARD. The LSI considers only longitudinal stability limitations,
observe all operating parameters. Failure to follow operating parameters of the
telehandler could damage the equipment and/or cause tip over.