JLG 660AJ Service Manual User Manual
Page 286
Advertising
SECTION 6 - JLG CONTROL SYSTEM
6-32
– JLG Lift –
3121616
NO ALTERNATOR OUTPUT
4
3
CLEARS WHEN FAULT IS REMOVED
OIL PRESSURE LOW
4
3
CLEARS WHEN FAULT IS REMOVED
485 COMMUNICATIONS LOST
4
3
CLEARS WHEN FAULT IS REMOVED
CAN BUS FAILURE
6
6
CLEARS WHEN FAULT IS REMOVED
LOAD SENSOR NOT CALIBRATED
9
9
CLEARS WHEN FAULT IS REMOVED
TILT SENSOR NOT CALIBRATED
9
9
CLEARS WHEN FAULT IS REMOVED
EEPROM FAILURE - CHECK ALL SETTINGS
9
9
REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT
PLATFORM MODULE FAILURE: HWFS CODE 1
9
9
CLEARS WHEN FAULT IS REMOVED
GROUND MODULE FAILURE: HWFS CODE 1
9
9
CLEARS WHEN FAULT IS REMOVED
Table 6-4. Help Message/Fault Listing
HELP MESSAGE
FAULT
FAULT REMOVAL
Advertising
This manual is related to the following products: