background image

SECTION 5 - HYDRAULICS

5-26

– JLG Lift –

3120679

8.

See that dowel pins are in place in any new cast-
ings. Examine all dowels. Before inserting make
sure the hole is clean and free from burrs. Gently
start pin straight into hole and tap lightly with a soft
hammer.

9.

Before inserting a new lip seal in the shaft end cover,
coat the outer edge of the lip seal and its recess with
Permatex Aviation Form-A-Gasket No. 3 non harden-
ing sealant or equivalent. With the metal side of the
lip seal up, press it into the mounting flange side of
the shaft end cover with an arbor press and bar. Be
careful not do damage the lip of the seal. Press in
until flush with the recess. Wipe off excess sealant.

10.

If the unit is equipped with an outboard bearing,
guide the bearing into it’s recess in the shaft end
cover. This is a light press fit. It may be necessary to
lightly tap the bearing into the bore.

11.

If the pump is equipped with an outboard bearing,
place the shaft end cover in the vise with the mount-
ing face up. Install the snap ring in the groove to
retain the outboard bearing.