SECTION 1 - SPECIFICATIONS

1-10

– JLG Lift –

3120679

27. Upper Master Cylinder Rod End

Lube Point(s) - 1 Grease Fitting
Capacity - A/R
Lube - MPG
Interval - Every 3 months or 150 hrs of operation
Comments -

28. Upper Master Cylinder Barrel End

Lube Point(s) - 1 Grease Fitting
Capacity - A/R
Lube - MPG
Interval - Every 3 months or 150 hrs of operation
Comments -

29. Tower Boom Lift Cylinder Rod End

Lube Point(s) - 1 Grease Fitting
Capacity - A/R
Lube - MPG
Interval - Every 3 months or 150 hrs of operation
Comments -

30. Hydraulic Oil

Lube Point(s) - Fill Cap/Drain Plug
Capacity - A/R
Lube - HO
Interval - Check daily. Change every 2 years or 1200

hours

Comments - On new machines, those recently over-

hauled, or after changing hydraulic oil, operate
all systems a minimum of two complete cycles
and recheck oil level in reservoir.

31. Hydraulic Filter

Interval - Replace filter after first 50 hours of opera-

tion, then every 6 months or 300 hours thereaf-
ter.

32. Air Filter

Lube Point(s) - Replaceable Element
Interval - Every 6 months or 300 hours of operation

or as indicated by the condition indicator