SECTION 1 - SPECIFICATIONS

1-6

– JLG Lift –

3120679

1. Torque Hubs

Lube Point(s) - 1 Fill Plug per hub
Capacity -
Lube - EPGL
Interval - Check oil level at side plug on hub weekly.

Change after first 3 months or 150 hours then
every 2 years or 1200 hours of operation.

Comments - Place Fill port at 12 o’clock position

and pour lubricant into fill port until it just starts
to flow out of check port when it’s at the 3
o’clock position.

2. Steer Spindles

Lube Point(s) - 4 Grease Fittings
Capacity - A/R
Lube - MPG
Interval - Every 3 months or 150 hrs of operation

3. Tie Rod Center Pivot Links

Lube Point(s) - 2 Grease Fittings
Capacity - A/R
Lube - MPG
Interval - Every 3 months or 150 hrs of operation

4. Steer Cylinder Barrel Ends

Lube Point(s) - 2 Grease Fittings
Capacity - A/R
Lube - MPG
Interval - Every 3 months or 150 hrs of operation

5. Steer Cylinder Rod Ends

Lube Point(s) - 2 Grease Fittings
Capacity - A/R
Lube - MPG
Interval - Every 3 months or 150 hrs of operation