JLG 150HAX ANSI Service Manual User Manual
Page 16
SECTION 1 - SPECIFICATIONS
1-6
– JLG Lift –
3120679
1. Torque Hubs
Lube Point(s) - 1 Fill Plug per hub
Capacity -
Lube - EPGL
Interval - Check oil level at side plug on hub weekly.
Change after first 3 months or 150 hours then
every 2 years or 1200 hours of operation.
Comments - Place Fill port at 12 o’clock position
and pour lubricant into fill port until it just starts
to flow out of check port when it’s at the 3
o’clock position.
2. Steer Spindles
Lube Point(s) - 4 Grease Fittings
Capacity - A/R
Lube - MPG
Interval - Every 3 months or 150 hrs of operation
3. Tie Rod Center Pivot Links
Lube Point(s) - 2 Grease Fittings
Capacity - A/R
Lube - MPG
Interval - Every 3 months or 150 hrs of operation
4. Steer Cylinder Barrel Ends
Lube Point(s) - 2 Grease Fittings
Capacity - A/R
Lube - MPG
Interval - Every 3 months or 150 hrs of operation
5. Steer Cylinder Rod Ends
Lube Point(s) - 2 Grease Fittings
Capacity - A/R
Lube - MPG
Interval - Every 3 months or 150 hrs of operation