Machine configuration programming information -15 – JLG M4069 Service Manual User Manual

Page 107

Advertising
background image

SECTION 5 - JLG CONTROL SYSTEM

3121639

– JLG Lift –

5-15

NOTE: When configuring an LE scissors machine, the

machine configuration must be completed before
any personality settings can be changed. Changing

the personality settings first and then changing the
model number of the machine configuration will
cause the personality settings to return to default.

Table 5-4. Machine Configuration Programming Information

Configuration Digit

Number

Description

Default Number

0

1

2

3

4

5

1

(MODEL #)

0
1

3369LE
4069LE

0

2

(MARKET)

0
1
2
3
4
5

ANSI USA

ANSI EXPORT

CSA

CE

AUSTRALIA

JAPAN

0

3

(TILT CUTOUT)

0
1

NO - Drive & Lift Up not prevented when Tilted & Elevated

YES - Drive & Lift Up prevented when Tilted & Elevated.

1

1

1

0

1

1

4

(LEVELING JACKS)

0
1

NO - Leveling Jacks are not installed.

YES - Leveling Jacks are installed.

0

5

(CHARGER INTRLOK)

0
1

DRIVE - Drive is prevented when the vehicle is being charged.

DRIVE & LIFT - Drive & Lift Up are prevented when the vehicle is being

charged.

0

6

(GROUND ALARM)

0
1
2

NOT INSTALLED - The Ground Alarm shall not sound

DESCENT - The Ground Alarm shall sound during Lift Down

MOTION - The Ground Alarm shall sound during any vehicle motion.

1

1

1

1

1

2

7

(FUNCTION CUTOUT)

0
1
2

NONE

DRV & LFT UP - Only allows Lift Down when Function Cutout is active.

ALL FUNCTIONS - All functions are prevented when Function Cutout is

active

0

8

(4 WHEEL ASSIST)

0
1

NO - The 4 Wheel Assist option is not installed.

YES - The 4 Wheel Assist option is installed.

0

9

(LOAD)

0
1

2

NOT INSTALLED - Load Sensing System (LSS) is not fitted to the vehicle.

CUTOUT PLT - LSS is fitted, and Platform Controls are prevented in the

event of an Overload. Ground Controls remain functional. This is the

default setting for CE machines.

CUTOUT ALL - LSS is fitted. Platform and Ground Controls are

prevented in the event of an Overload

0

1

0

1

0

1

10

(TILT LIMIT)*

0
1

STANDARD - Normal tilt limits.

SPECIAL 1 - Vehicle tilt limits restricted to allow operation of a standard

3369LE in 16.7 m/s wind speeds for the CE Market.

NOTE: Tilt Limit selection is only visible for the 3369LE con-

figured for the CE Market. The selection will default
to STANDARD otherwise.

0

0

0

0

0

0

4150352_G