SECTION 6 - GENERAL ELECTRICAL INFORMATION & SCHEMATICS

6-10

– JLG Lift –

3121639

6.4 WORKING WITH DEUTSCH

CONNECTORS

DT/DTP Series Assembly

Figure 6-12. DT/DTP Contact Installation

1. Grasp crimped contact about 25mm behind the con-

tact barrel.

2. Hold connector with rear grommet facing you.

3. Push contact straight into connector grommet until a

click is felt. A slight tug will confirm that it is properly
locked in place.

4. Once all contacts are in place, insert wedgelock with

arrow pointing toward exterior locking mechanism.
The wedgelock will snap into place. Rectangular
wedges are not oriented. Thy may go in either way.

NOTE: The receptacle is shown - use the same procedure

for plug.

DT/DTP Series Disassembly

Figure 6-13. DT/DTP Contact Removal

1. Remove wedgelock using needlenose pliers or a

hook shaped wire to pull wedge straight out.

2. To remove the contacts, gently pull wire backwards,

while at the same time releasing the locking finger
by moving it away from the contact with a screw-
driver.

3. Hold the rear seal in place, as removing the contact

may displace the seal.

HD30/HDP20 Series Assembly

Figure 6-14. HD/HDP Contact Installation

1. Grasp contact about 25mm behind the contact

crimp barrel.

2. Hold connector with rear grommet facing you.

3. Push contact straight into connector grommet until a

positive stop is felt. A slight tug will confirm that it is
properly locked in place.

Figure 6-15. HD/HDP Locking Contacts Into Position

NOTE: For unused wire cavities, insert sealing plugs for full

environmental sealing.

Advertising
This manual is related to the following products: