SECTION 3 - TROUBLESHOOTING

3-2

– JLG Sizzor –

3120768

Table 3-1. Platform Assembly Troubleshooting

TROUBLE

PROBABLE CAUSE

REMEDY

PLATFORM ELEVATION SYSTEM

No response to control switch

Enable switch not activated

Activate enable switch

Function not activated within 3 seconds after
enable switch was depressed

Reactivate enable switch

Enable switch not functioning properly

Replace enable switch circuit card

Lift control switch inoperative

Replace control switch

Hydraulic oil system low

Replenish oil system necessary

Restricted or broken supply line on valve or pump

Clean, repair or replace as necessary

Control valve not functioning properly

Repair or replace valve

Lift cylinder not functioning properly

Repair or replace lift cylinder

Hydraulic pump not functioning properly

Check Sevcon control contactors for proper func-
tioning

Low battery voltage

Check voltage and charge batteries or replace
batteries as necessary

Platform will not raise

Enable switch not activated

Activate enable switch

Function not activated within 3 seconds after
enable switch was depressed

Reactivate enable switch

Enable switch not functioning properly

Replace enable switch circuit card

Load capacity exceeded. (Personnel and/or
equipment on platform)

Reduce load to recommended capacity

Hydraulic oil system low

Replenish oil as necessary

Restricted or broken oil line or fitting

Clean, repair or replace as necessary

Control valve not functioning properly

Repair or replace valve

Lift cylinder not functioning properly

Repair or replace lift cylinder

Motor/Pump does not respond when lift control
switch is moved to the up position

Refer to the electrical schematic and/or electrical
system troubleshooting chart

No electrical signal being sent to lift up control
valve cartridge

Refer to the electrical schematic and/or electrical
system troubleshooting chart

Pressure set to low on pump

Check pressure and reset as necessary

Platform will not lower

No electrical signal being sent to lift down control
valve cartridge

Refer to the electrical schematic and/or electrical
system troubleshooting chart

Lift down control cartridge not functioning prop-
erly

Repair or replace lift down control cartridge

Lift cylinder not functioning properly

Repair or replace lift cylinder